全膝关节假体术中屈膝位松弛度评估

Intraoperative assessment of midflexion laxity in total knee prosthesis.

作者信息

Minoda Yukihide, Nakagawa Shigeru, Sugama Ryo, Ikawa Tessyu, Noguchi Takahiro, Hirakawa Masashi, Nakamura Hiroaki

机构信息

Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585, Japan.

Department of Orthopaedic Surgery, Osaka Rosai Hospital, 1179-3, Nagasone-cho, Kita-ku, Sakai, Osaka 591-8025, Japan.

出版信息

Knee. 2014 Aug;21(4):810-4. doi: 10.1016/j.knee.2014.04.010. Epub 2014 Apr 26.

Abstract

BACKGROUND

Soft-tissue balancing of the knee is fundamental to the success of a total knee arthroplasty (TKA). In posterior-stabilized TKA, there is no stabilizer of the anterior-posterior translation in the midflexion range in which the cam-post mechanism does not engage yet. Therefore, instability in the midflexion range is suspected to occur in posterior-stabilized TKA. The purpose of this study was to measure the joint gap throughout a full range of motion and to analyze the joint gap laxity in the midflexion range after implantation of a mobile-bearing posterior-stabilized total knee prosthesis.

METHODS

Joint gap kinematics in 259 knees with varus osteoarthritis were measured during TKAs using a tensor device with the same shape of a total knee prosthesis of the same design was used. After the implantation of a mobile-bearing posterior-stabilized prosthesis and the reduction of the patellofemoral joint, the joint gap was measured at 0°, 30°, 60°, 90°, 120°, and 145° of flexion.

RESULTS

The center size of the joint gap was tight in extension and deep flexion and loose at midflexion ranges, especially at 30° of flexion (p<0.001). The symmetry of the joint gap was varus at 0° and 145° of flexion (p<0.001).

CONCLUSIONS

Our results showed the joint gap laxity in the midflexion range after the implantation of a mobile-bearing posterior-stabilized prosthesis. Our new tensor device, which can attach the polyethylene insert trial, will provide the important information about the joint gap kinematics after implantation of total knee prostheses.

LEVEL OF EVIDENCE

IV.

摘要

背景

膝关节软组织平衡是全膝关节置换术(TKA)成功的基础。在后稳定型TKA中,在屈膝范围中部,凸轮-立柱机制尚未起作用时,没有前后平移的稳定器。因此,怀疑后稳定型TKA在屈膝范围中部会出现不稳定。本研究的目的是测量全膝关节活动范围内的关节间隙,并分析植入活动平台后稳定型全膝关节假体后屈膝范围中部的关节间隙松弛情况。

方法

在TKA手术期间,使用与相同设计的全膝关节假体形状相同的张量装置,测量259例内翻性骨关节炎患者膝关节的关节间隙运动学。植入活动平台后稳定型假体并复位髌股关节后,在屈膝0°、30°、60°、90°、120°和145°时测量关节间隙。

结果

关节间隙的中心尺寸在伸直位和极度屈膝时紧密,在屈膝范围中部松弛,尤其是在屈膝30°时(p<0.001)。关节间隙的对称性在屈膝0°和145°时为内翻(p<0.001)。

结论

我们的结果显示了植入活动平台后稳定型假体后屈膝范围中部的关节间隙松弛情况。我们的新型张量装置,能够连接聚乙烯衬垫试模,将为全膝关节假体植入后的关节间隙运动学提供重要信息。

证据等级

IV级。