Major Paul W, Toogood Roger W, Badawi Hisham M, Carey Jason P, Seru Surbhi
Department of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alta, Canada.
Faculty of Engineering, University of Alberta, Edmonton, Alta, Canada.
J Orthod. 2014 Dec;41(4):285-91. doi: 10.1179/1465313314Y.0000000099. Epub 2014 May 22.
To better understand the effects of copper nickel titanium (CuNiTi) archwire size on bracket-archwire mechanics through the analysis of force/couple distributions along the maxillary arch. The hypothesis is that wire size is linearly related to the forces and moments produced along the arch.
An Orthodontic Simulator was utilized to study a simplified high canine malocclusion. Force/couple distributions produced by passive and elastic ligation using two wire sizes (Damon 0.014 and 0.018 inch) measured with a sample size of 144.
The distribution and variation in force/couple loading around the arch is a complicated function of wire size. The use of a thicker wire increases the force/couple magnitudes regardless of ligation method. Owing to the non-linear material behaviour of CuNiTi, this increase is less than would occur based on linear theory as would apply for stainless steel wires.
The results demonstrate that an increase in wire size does not result in a proportional increase of applied force/moment. This discrepancy is explained in terms of the non-linear properties of CuNiTi wires. This non-proportional force response in relation to increased wire size warrants careful consideration when selecting wires in a clinical setting.
通过分析沿上颌牙弓的力/力矩分布,更好地理解铜镍钛(CuNiTi)弓丝尺寸对托槽-弓丝力学性能的影响。假设是弓丝尺寸与沿牙弓产生的力和力矩呈线性相关。
利用正畸模拟器研究一种简化的高角犬牙错颌。使用两种弓丝尺寸(Damon 0.014英寸和0.018英寸),通过被动结扎和弹性结扎产生力/力矩分布,样本量为144。
牙弓周围力/力矩加载的分布和变化是弓丝尺寸的复杂函数。无论结扎方法如何,使用较粗的弓丝都会增加力/力矩的大小。由于CuNiTi的非线性材料特性,这种增加小于基于适用于不锈钢丝的线性理论所预测的增加。
结果表明,弓丝尺寸的增加不会导致施加的力/力矩成比例增加。这种差异可以用CuNiTi丝的非线性特性来解释。在临床环境中选择弓丝时,这种与弓丝尺寸增加相关的非比例力响应值得仔细考虑。