Vito R P, Shin T J, McCarey B E
School of Mechanical Engineering, Georgia Institute of Technology, Atlanta 30332.
Refract Corneal Surg. 1989 Mar-Apr;5(2):82-8.
A finite element-based computer simulation of radial keratotomy surgery was conducted to study, in particular, curvature changes of the central clear zone in human cornea under various physiological and surgical conditions. Corneal tissue was assumed to behave as a nearly incompressible, linear elastic, homogeneous, isotropic material undergoing small deformation. The Young's modulus was determined by using the model to predict the surgical outcome of a representative patient. The results of the simulation are in qualitative agreement with clinical experience indicating the potential of finite element modeling as an aid to the surgeon in evaluating variables.
进行了基于有限元的放射状角膜切开术计算机模拟,以特别研究在各种生理和手术条件下人类角膜中央透明区的曲率变化。假定角膜组织表现为一种几乎不可压缩、线性弹性、均匀、各向同性的材料,经历小变形。通过使用该模型预测一名代表性患者的手术结果来确定杨氏模量。模拟结果与临床经验在定性上一致,表明有限元建模在帮助外科医生评估变量方面的潜力。