Suppr超能文献

经巩膜、角巩膜缘或角膜切口行虹膜夹型人工晶状体植入术后散光的比较。

Comparison of surgically induced astigmatism following iris-claw PIOL insertion with scleral, limbal, or corneal incisions.

出版信息

J Refract Surg. 2014 May;30(5):330-5. doi: 10.3928/1081597X-20140416-02.

Abstract

PURPOSE

To compare surgically induced astigmatism (SIA) based on incision site and evaluate the clinical results and astigmatic stability of iris-claw phakic intraocular lens (Artisan lens; Ophtec BV, Groningen, Netherlands) implantation.

METHODS

Eighty-five eyes of 53 patients with myopia who underwent Artisan lens implantation with a 6.2-mm incision and follow-up of 6 months were retrospectively observed. SIA was assessed using keratometric astigmatism at 6 months postoperatively for the incision sites of the sclera, limbus, and cornea, and the efficacy, safety, predictability, and astigmatic stability were also calculated.

RESULTS

SIA obtained using Naeser's polar method (KP[90]SIA) was -0.48 ± 0.35 for scleral incisions, -0.99 ± 0.35 for limbal incisions, and -1.14 ± 0.54 for corneal incisions. Corresponding net astigmatism values, as calculated with KP(90)SIA and KP(135)SIA, were 0.70 ± 0.48 (177°), 1.04 ± 0.37 (175°), and 1.21 ± 0.57 (1°), respectively, with SIA increasing the nearer the incision was to the cornea center. Six months after surgery, the efficacy index was 1.03 and the safety index was 1.08. Ninety-eight percent of patients were within 1.50 diopters of attempted refraction.

CONCLUSIONS

The values of SIA after Artisan lens insertion showed significant differences among three incision locations, despite the absence of significant differences in preoperative steep corneal axis astigmatism values at the incision locations. It would be applicable for refractive surgery in the aspect of minimizing astigmatism after surgery.

摘要

目的

比较基于切口部位的手术源性散光(SIA),并评估虹膜夹型有晶状体眼人工晶状体(Artisan 晶状体;荷兰格罗宁根 Ophtec BV)植入的临床结果和散光稳定性。

方法

回顾性观察了 53 名近视患者的 85 只眼,这些患者接受了 6.2mm 切口的 Artisan 晶状体植入术,随访 6 个月。通过术后 6 个月角膜散光测量评估切口部位的巩膜、角膜缘和角膜的 SIA,并计算疗效、安全性、可预测性和散光稳定性。

结果

使用 Naeser 极角法(KP[90]SIA)测量的 SIA 结果为巩膜切口处为-0.48±0.35,角膜缘切口处为-0.99±0.35,角膜切口处为-1.14±0.54。用 KP(90)SIA 和 KP(135)SIA 计算的相应净散光值分别为 0.70±0.48(177°)、1.04±0.37(175°)和 1.21±0.57(1°),切口越接近角膜中心,SIA 越大。术后 6 个月时,疗效指数为 1.03,安全指数为 1.08。98%的患者屈光度在 1.50 屈光度以内。

结论

尽管切口部位术前陡峭角膜轴散光值无显著差异,但 Artisan 晶状体植入术后 SIA 值在三个切口部位存在显著差异。从术后散光最小化的角度来看,它可适用于屈光手术。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验