• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Studies on the influences of the indirect retainers on the displacements of the denture bases and the abutment teeth. 2. The forms and locations of indirect retainers used for cross arch stabilizations].

作者信息

Saito M

出版信息

Nihon Hotetsu Shika Gakkai Zasshi. 1989 Apr;33(2):337-51. doi: 10.2186/jjps.33.337.

DOI:10.2186/jjps.33.337
PMID:2489568
Abstract

The purpose of this experimental study is to investigate and evaluate characteristic movements of the denture bases and the abutment teeth, when the forms and locations of the indirect retainers used for the cross arch stabilization are altered. The results are as follows: 1. Under the vertical forces, the increases of abutment tooth excursion and denture base movement are observed, when the fulcrum line crosses the "loading axis" at nearly right angle. 2. When the vertical forces are applied, the displacements of abutment tooth and denture base with two indirect retainers are more reduction than that with one. 3. The distances between two indirect retainers used for cross arch stabilization increase, the less displacements of abutment tooth and denture base are. 4. When the partial denture has only one indirect retainer used for the cross arch stabilization, it is important that the positive rest is located on the anterior tooth and the indirect retainer is placed on as distal tooth as possible. 5. If the occlusal forces are supported by the residual ridge, it may be better designs that the positive rest is located on the anterior tooth and the Akers clasp with mesial rest or the double Akers clasp is located on the premolars.

摘要

相似文献

1
[Studies on the influences of the indirect retainers on the displacements of the denture bases and the abutment teeth. 2. The forms and locations of indirect retainers used for cross arch stabilizations].
Nihon Hotetsu Shika Gakkai Zasshi. 1989 Apr;33(2):337-51. doi: 10.2186/jjps.33.337.
2
An investigation of the effectiveness of indirect retainers.间接固位体有效性的研究。
J Prosthet Dent. 1977 Nov;38(5):494-506. doi: 10.1016/0022-3913(77)90024-5.
3
The effects of loading locations and direct retainers on the movements of the abutment tooth and denture base of removable partial dentures.加载位置和直接固位体对可摘局部义齿基牙和义齿基托移动的影响。
J Med Dent Sci. 2002 Mar;49(1):11-8.
4
An analysis of stress distribution in the free-end saddles on the mandibular model.下颌模型游离端鞍基应力分布分析
Bull Tokyo Med Dent Univ. 1975 Sep;22(3):221-34.
5
Stress distribution and abutment tooth mobility of distal-extension removable partial dentures with different retainers: an in vivo study.不同固位体的远中游离可摘局部义齿的应力分布及基牙移动度:一项体内研究
J Oral Rehabil. 1999 Feb;26(2):111-6. doi: 10.1046/j.1365-2842.1999.00345.x.
6
Influence of loading positions of mandibular unilateral distal extension removable partial dentures on movements of abutment tooth and denture base.下颌单侧远中游离端可摘局部义齿加载位置对基牙及义齿基托运动的影响
J Med Dent Sci. 2004 Sep;51(3):155-63.
7
An analysis of rotational movement of asymmetrical distal-extension removable partial dentures.不对称远中伸展可摘局部义齿旋转运动分析
J Prosthet Dent. 1989 Feb;61(2):211-4. doi: 10.1016/0022-3913(89)90376-4.
8
Motion vector analysis of an abutment for a distal-extension removable partial denture: a pilot study.远中游离可摘局部义齿基牙的运动向量分析:一项初步研究。
J Prosthet Dent. 1980 Jan;43(1):15-21. doi: 10.1016/0022-3913(80)90346-7.
9
Force transmission by indirect retainers when a unilateral dislodging force is applied.施加单侧脱位力时间接固位体的力传递。
J Prosthet Dent. 1982 Apr;47(4):360-5. doi: 10.1016/s0022-3913(82)80081-4.
10
Stress distribution of abutments and base displacement with precision attachment- and telescopic crown-retained removable partial dentures.精密附着体和套筒冠固位可摘局部义齿基牙的应力分布及基托位移
J Oral Rehabil. 2003 May;30(5):482-7. doi: 10.1046/j.1365-2842.2003.01092.x.