We report an outbreak of surgical site infections due to genetically related strains of Streptococcus pyogenes in a cardiovascular surgery department.
The practices that were possibly related to the outbreak were investigated through direct observation and interviews with staff by an infection control team. Surveillance sampling from patients, health-care workers, and environment were done for the investigation of the source. Pulsed-field gel electrophoresis was used to investigate a clonal relationship among the S. pyogenes isolates.
Four patients operated on in the cardiovascular surgery department developed surgical site infection due to S. pyogenes. Molecular characterization of S. pyogenes done by pulsed-field gel electrophoresis revealed the same strain.
Although a definite source for the outbreak could not be identified, probably lack of adherence to hand hygiene practices during surgical dressings, contamination, and cross contamination led to this outbreak.
我们报告了心血管外科中由遗传相关的化脓性链球菌菌株引起的手术部位感染暴发。
感染控制团队通过直接观察和与工作人员访谈,对可能与暴发相关的操作进行了调查。对患者、医护人员和环境进行监测采样以调查源头。采用脉冲场凝胶电泳来研究化脓性链球菌分离株之间的克隆关系。
心血管外科的4名接受手术的患者发生了由化脓性链球菌引起的手术部位感染。通过脉冲场凝胶电泳对化脓性链球菌进行的分子特征分析显示为同一菌株。
尽管无法确定暴发的确切源头,但手术敷料期间可能未严格遵守手部卫生规范、污染和交叉污染导致了此次暴发。