Mu Yonglin, Zeng Jiawei, Chen Qianqian, Liu Jia, Wang Lili, Yao Fujia, Cui Meng, He Zhixiang, Zhang Chiyu, Xiao Ming, Lan Ke
College of Life and Environmental Science, Shanghai Normal University, Shanghai, China; Pathogen Diagnostic Center, Institut Pasteur of Shanghai, Chinese Academy of Science, Shanghai, China.
Dujiangyan Medical Center, Dujiangyan City, Sichuan, China.
J Virol Methods. 2014 Sep;206:84-8. doi: 10.1016/j.jviromet.2014.06.005. Epub 2014 Jun 9.
Human respiratory syncytial virus (HRSV) is a seasonal respiratory pathogen that causes respiratory infection in children and the elderly. A new, reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay was developed for the rapid (within 1h), simultaneous detection of A and B group HRSV. Primers specific for groups A and B were designed to amplify the N and L genes of HRSV, respectively. A fluorescent dye, calcein, was used as an indicator for the endpoint visual detection and/or real-time amplification of HRSV RNA. The detection limit of the new method was 281.17 50% tissue culture infective doses (TCID50)/ml for HRSV A and 1.58 TCID50/ml for HRSV B. To evaluate the validity of this method, a comparison with RT-PCR was performed using 77 nasopharyngeal swabs as samples. Both RT-LAMP and RT-PCR detected HRSV in 38 HRSV samples, yielding a positive rate of 49%. Of the RT-LAMP positive samples, 36 (95%) were also positive by RT-PCR, while two were negative by RT-PCR. Among the 36 RT-LAMP and RT-PCR positive samples, 11 belonged to HRSV group A, while 25 belonged to group B. The results show that the new RT-LAMP is simple, rapid and well suited for HRSV diagnosis, especially in a limited-resource setting.
人呼吸道合胞病毒(HRSV)是一种季节性呼吸道病原体,可导致儿童和老年人发生呼吸道感染。开发了一种新的逆转录环介导等温扩增(RT-LAMP)检测方法,用于快速(1小时内)同时检测A组和B组HRSV。分别设计了针对A组和B组的引物,以扩增HRSV的N基因和L基因。荧光染料钙黄绿素用作HRSV RNA终点可视化检测和/或实时扩增的指示剂。该新方法对HRSV A的检测限为281.17 50%组织培养感染剂量(TCID50)/ml,对HRSV B的检测限为1.58 TCID50/ml。为评估该方法的有效性,以77份鼻咽拭子为样本与RT-PCR进行了比较。RT-LAMP和RT-PCR在38份HRSV样本中均检测到HRSV,阳性率为49%。在RT-LAMP阳性样本中,36份(95%)RT-PCR也呈阳性,2份RT-PCR呈阴性。在36份RT-LAMP和RT-PCR均阳性的样本中,11份属于HRSV A组,25份属于B组。结果表明,新的RT-LAMP方法简单、快速,非常适合HRSV诊断,尤其是在资源有限的情况下。