Suppr超能文献

种植体植入后的 X 射线参数可预测腹膜透析中功能性导管问题。

Postimplantation X-ray parameters predict functional catheter problems in peritoneal dialysis.

机构信息

1] Department of Nephrology, Dialysis and Renal Transplantation, University Hospitals Leuven, Leuven, Belgium [2] Laboratory of Nephrology, Department of Microbiology and Immunology, KU Leuven, Leuven, Belgium.

Department of Nephrology, Dialysis and Renal Transplantation, University Hospitals Leuven, Leuven, Belgium.

出版信息

Kidney Int. 2014 Nov;86(5):1001-6. doi: 10.1038/ki.2014.203. Epub 2014 Jun 18.

Abstract

Functional catheter problems are a major challenge for peritoneal dialysis (PD) programs. Here we performed a retrospective single-center study of 110 consecutive patients receiving a first PD catheter (swan neck double-cuff Missouri curled catheters, open surgical technique). Using postimplantation X-ray, the following categories were defined: swan neck angle (posterioanterio view (PA): under 45°, 45-90°, over 90°), inclination (angle between intramural part of catheter and horizontal line; lateral view: greater than/equal to 30°, under 30°), and the position of silicone bead relative to spine (PA view: L1-2, L3-4, lower) and catheter tip (PA view: hypogastric, umbilical, subcostal). Covariates included demographics, body size, previous abdominal surgery, and abdominal wall hernias. During a mean follow-up of 36 months, the time to first functional catheter problem was significantly associated with both the swan neck angle and inclination. The need for surgical intervention was significantly associated with inclination only. Technique failure was not associated with any parameter. In multivariate analysis, inclination was the sole variable significantly associated with functional catheter problems (hazard ratio 3.65 [1.98-6.72]) and the need for surgical intervention (hazard ratio 2.86 [1.19-6.88]). Thus, our study defines a set of X-ray variables that predict functional PD catheter problems and can be used for troubleshooting in individual cases as well as for education and internal audit purposes.

摘要

功能性导管问题是腹膜透析(PD)项目的主要挑战。在这里,我们对 110 例连续接受首次 PD 导管(天鹅颈双袖套密苏里卷曲导管,开放式手术技术)的患者进行了回顾性单中心研究。使用植入后的 X 射线,定义了以下类别:天鹅颈角度(后前位(PA):小于 45°、45-90°、大于 90°)、倾斜度(导管壁内部分与水平线之间的角度;侧位:大于/等于 30°、小于 30°),以及硅珠相对于脊柱的位置(PA 视图:L1-2、L3-4、下部)和导管尖端(PA 视图:耻骨、脐、肋缘下)。协变量包括人口统计学、体型、既往腹部手术和腹壁疝。在平均 36 个月的随访期间,首次功能性导管问题的时间与天鹅颈角度和倾斜度显著相关。手术干预的需要仅与倾斜度显著相关。技术失败与任何参数均无关。多变量分析中,倾斜度是唯一与功能性导管问题(风险比 3.65 [1.98-6.72])和手术干预需要(风险比 2.86 [1.19-6.88])显著相关的变量。因此,我们的研究定义了一组 X 射线变量,可以预测功能性 PD 导管问题,并可用于个别病例的故障排除以及教育和内部审计目的。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验