Loochtan Michael J, Yang Shiayin, Mantravadi Avinash V, Marzo Sam J
Cochlear Implants Int. 2014 Sep;15(5):276-8. doi: 10.1179/1754762814Y.0000000078. Epub 2014 Jun 20.
The goal of this paper is to describe a previously unreported etiology for cochlear implant extrusion. A short literature review is included. This paper represents the first reported case of cochlear implant extrusion secondary to keloid formation.
We present the case of a 40-year-old male who underwent cochlear implant insertion approximately 5 years prior who later developed a 5 cm post-auricular soft tissue swelling and partial extrusion which interfered with implant function.
He subsequently underwent wound debridement, cochlear implant removal, and rotational skin flap closure. Final pathology revealed keloid scar.
Cochlear implant extrusion is a rare complication which has been attributed to various causes. This report identifies keloid formation as another possible source.
本文旨在描述一种此前未报道过的人工耳蜗植入体脱出病因。文中包含简短的文献综述。本文报道了首例因瘢痕疙瘩形成导致人工耳蜗植入体脱出的病例。
我们报告一例40岁男性病例,该患者大约5年前接受了人工耳蜗植入,后来出现了5厘米的耳后软组织肿胀和部分植入体脱出,影响了植入体功能。
他随后接受了伤口清创、人工耳蜗移除及旋转皮瓣闭合术。最终病理检查显示为瘢痕疙瘩。
人工耳蜗植入体脱出是一种罕见的并发症,其病因多种多样。本报告指出瘢痕疙瘩形成是另一个可能的原因。