de-Azevedo-Vaz Sergio Lins, Oenning Anne Caroline Costa, Felizardo Marcela Graciano, Haiter-Neto Francisco, de Freitas Deborah Queiroz
Department of Clinical Dentistry, Faculty of Dentistry, Federal University of Espirito Santo, Vitoria, Espirito Santo, Brazil,
Clin Oral Investig. 2015 Apr;19(3):583-8. doi: 10.1007/s00784-014-1277-3. Epub 2014 Jul 4.
The objective of this study is to assess the accuracy of the vertical tube shift method in identifying the relationship between the mandibular canal (MC) and third molars.
Two examiners assessed image sets of 173 lower third molar roots (55 patients) using forced consensus. The image sets comprised two methods: PERI, two periapical radiographs (taken at 0° and -30°), and PAN, a panoramic radiograph (vertical angulation of -8°) and a periapical radiograph taken at a vertical angulation of -30°. Cone beam computed tomography (CBCT) was the reference standard in the study. The responses were recorded for position (buccal, in-line with apex and lingual) and contact (present or absent). The McNemar-Bowker and McNemar tests were used to determine if the PERI and PAN methods would disagree with the reference standard (α = 5 %).
The PERI and PAN methods disagreed with the reference standard for both position and contact (p < 0.05).
The vertical tube shift method was not accurate in determining the relationship between lower third molars and the MC.
The vertical tube shift is not a reliable method for predicting the relationship between lower third molars and the MC.
本研究的目的是评估垂直管移位法在确定下颌管(MC)与第三磨牙之间关系时的准确性。
两名检查者采用强制一致性评估了173颗下颌第三磨牙牙根(55例患者)的影像集。影像集包括两种方法:PERI,两张根尖片(分别在0°和 -30°拍摄),以及PAN,一张全景片(垂直角度为 -8°)和一张垂直角度为 -30°拍摄的根尖片。锥形束计算机断层扫描(CBCT)是本研究中的参考标准。记录关于位置(颊侧、根尖连线及舌侧)和接触情况(存在或不存在)的反应。使用McNemar-Bowker检验和McNemar检验来确定PERI和PAN方法是否与参考标准不一致(α = 5%)。
PERI和PAN方法在位置和接触情况上均与参考标准不一致(p < 0.05)。
垂直管移位法在确定下颌第三磨牙与下颌管之间的关系时不准确。
垂直管移位不是预测下颌第三磨牙与下颌管之间关系的可靠方法。