Suppr超能文献

金属对金属髋关节表面置换翻修术后的结果

Outcomes after revision of metal-on-metal hip resurfacing arthroplasty.

作者信息

Gross Thomas P, Liu Fei

机构信息

Midlands Orthopaedics, P.A., Columbia, South Carolina.

出版信息

J Arthroplasty. 2014 Sep;29(9 Suppl):219-23. doi: 10.1016/j.arth.2014.01.036. Epub 2014 May 27.

Abstract

We report the results of 58 hip resurfacing arthroplasties (HRA) revised by a single surgeon with an average of 5.2±2.6 years follow-up. The four most common causes for revision were acetabular component loosening, femoral neck fracture, femoral component loosening, and adverse wear related failure (AWRF). In 95% of cases (55/58), the revision bearing was a large metal-on-metal type including all seven AWRF cases; three cases were revised to ceramic-on-polyethylene. There were two repeat revisions due to acetabular component loosening. Revision of AWRF had an excellent outcome using limited debridement and a stable large metal bearing placed in the correct position. The only problematic group was the one revised for acetabular loosening in which 2/16 (6%) required repeat revision for failure of acetabular fixation.

摘要

我们报告了由同一位外科医生进行翻修的58例髋关节表面置换术(HRA)的结果,平均随访时间为5.2±2.6年。翻修的四个最常见原因是髋臼组件松动、股骨颈骨折、股骨组件松动和不良磨损相关失败(AWRF)。在95%的病例(55/58)中,翻修时的轴承是大型金属对金属类型,包括所有7例AWRF病例;3例翻修为陶瓷对聚乙烯。有2例因髋臼组件松动而再次翻修。对AWRF进行翻修时,采用有限清创术并在正确位置放置稳定的大型金属轴承,结果极佳。唯一有问题的组是因髋臼松动而翻修的组,其中2/16(6%)因髋臼固定失败需要再次翻修。