Vocal fold oscillation patterns in tenors singing at high pitches (stage voice above the passaggio) are not yet understood in detail.
Nine professional opera tenors performed a transition from modal register (220 Hz) to falsetto or stage voice above the passaggio (440 Hz) on an /i/ vowel. High-speed digital imaging was performed using a rigid laryngoscopic system with a frame rate of 4,000 frames per second.
During the transition to stage voice above the passaggio seven out of nine tenors exhibited a strong retraction of the epiglottis with rising F0, which prevented further analysis of vocal fold oscillations. During transitions to falsetto many supraglottic modifications were also observed.
Tenor stage voice above the passaggio seems to be typically associated with retraction of the epiglottis for the vowel /i/ thus preventing examination of vocal fold oscillations using rigid laryngoscopy.
男高音在高音区(换声区以上的舞台声区)的声带振荡模式尚未得到详细了解。
九名职业歌剧男高音在发/i/元音时从正常发声区(220赫兹)过渡到假声或换声区以上的舞台声区(440赫兹)。使用帧率为每秒4000帧的刚性喉镜系统进行高速数字成像。
在过渡到换声区以上的舞台声区时,九名男高音中有七名随着基频升高会出现会厌强烈后缩,这妨碍了对声带振荡的进一步分析。在过渡到假声时,也观察到许多声门上的变化。
换声区以上的男高音舞台声区似乎通常与发/i/元音时会厌后缩有关,因此无法使用刚性喉镜检查声带振荡。