Abstract

RATIONALE AND OBJECTIVES

To evaluate whether the presence of facial photographs obtained at the point-of-care of portable radiography leads to increased detection of wrong-patient errors.

MATERIALS AND METHODS

In this institutional review board-approved study, 166 radiograph-photograph combinations were obtained from 30 patients. Consecutive radiographs from the same patients resulted in 83 unique pairs (ie, a new radiograph and prior, comparison radiograph) for interpretation. To simulate wrong-patient errors, mismatched pairs were generated by pairing radiographs from different patients chosen randomly from the sample. Ninety radiologists each interpreted a unique randomly chosen set of 10 radiographic pairs, containing up to 10% mismatches (ie, error pairs). Radiologists were randomly assigned to interpret radiographs with or without photographs. The number of mismatches was identified, and interpretation times were recorded.

RESULTS

Ninety radiologists with 21 ± 10 (mean ± standard deviation) years of experience were recruited to participate in this observer study. With the introduction of photographs, the proportion of errors detected increased from 31% (9 of 29) to 77% (23 of 30; P = .006). The odds ratio for detection of error with photographs to detection without photographs was 7.3 (95% confidence interval: 2.29-23.18). Observer qualifications, training, or practice in cardiothoracic radiology did not influence sensitivity for error detection. There is no significant difference in interpretation time for studies without photographs and those with photographs (60 ± 22 vs. 61 ± 25 seconds; P = .77).

CONCLUSIONS

In this observer study, facial photographs obtained simultaneously with portable chest radiographs increased the identification of any wrong-patient errors, without substantial increase in interpretation time. This technique offers a potential means to increase patient safety through correct patient identification.

摘要

原理与目的

评估在便携式放射成像即时护理点获取面部照片是否会增加对错误患者错误的检测。

材料与方法

在这项经机构审查委员会批准的研究中,从30名患者获取了166张X光照片 - 照片组合。同一患者的连续X光照片产生了83对独特的组合(即一张新的X光照片和之前的对比X光照片)用于解读。为模拟错误患者错误,通过将从样本中随机选择的不同患者的X光照片配对来生成不匹配的组合。90名放射科医生每人解读一组随机选择的独特的10对X光照片,其中不匹配的比例最高为10%(即错误组合)。放射科医生被随机分配解读有或没有照片的X光照片。确定不匹配的数量,并记录解读时间。

结果

招募了90名平均经验为21±10(均值±标准差)年的放射科医生参与这项观察性研究。随着照片的引入,检测到的错误比例从31%(29例中的9例)增加到77%(30例中的23例;P = 0.006)。有照片时检测到错误与无照片时检测到错误的比值比为7.3(95%置信区间:2.29 - 23.18)。观察者在心胸放射学方面的资质、培训或实践经验并未影响错误检测的敏感性。无照片的研究与有照片的研究在解读时间上无显著差异(60±22秒对61±25秒;P = 0.77)。

结论

在这项观察性研究中,与便携式胸部X光照片同时获取的面部照片增加了对任何错误患者错误的识别,且解读时间没有大幅增加。这项技术提供了一种通过正确识别患者来提高患者安全的潜在方法。

相似文献

引用本文的文献

5
Patient Photographs: Privacy Versus Protection.患者照片:隐私与保护的权衡
AJR Am J Roentgenol. 2019 Feb;212(2):320-322. doi: 10.2214/AJR.18.20452. Epub 2018 Nov 26.

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验