Suppr超能文献

在一项使用胰岛细胞产品的试点研究中,运用BacT/alert系统快速检测微生物污染情况。

Use of the BacT/alert system for rapid detection of microbial contamination in a pilot study using pancreatic islet cell products.

作者信息

Murray Laura, McGowan Neil, Fleming John, Bailey Laura

机构信息

Donation Testing Department, Scottish National Blood Transfusion Service, Glasgow, Scotland.

SNBTS Cell Therapy Development Centre, Scottish National Blood Transfusion Service, The University of Edinburgh, Edinburgh bioQuarter, Edinburgh, Scotland.

出版信息

J Clin Microbiol. 2014 Oct;52(10):3769-71. doi: 10.1128/JCM.00447-14. Epub 2014 Jul 16.

Abstract

At the Islet Isolation Laboratory of the Scottish National Blood Transfusion Service, manual sterility testing data show that contamination rates are 57.7% for pancreas transport fluid, 4.3% for postpurification islet samples, and 0% for pretransplant islet samples. This pilot study presents the BacT/Alert System as an alternative to manual testing to provide more rapid and sensitive sterility results for islet cell products.

摘要

在苏格兰国家血液输血服务中心的胰岛分离实验室,人工无菌检测数据显示,胰腺运输液的污染率为57.7%,纯化后胰岛样本的污染率为4.3%,移植前胰岛样本的污染率为0%。这项初步研究介绍了BacT/Alert系统,作为人工检测的替代方法,可为胰岛细胞产品提供更快速、灵敏的无菌检测结果。

相似文献

1
Use of the BacT/alert system for rapid detection of microbial contamination in a pilot study using pancreatic islet cell products.
J Clin Microbiol. 2014 Oct;52(10):3769-71. doi: 10.1128/JCM.00447-14. Epub 2014 Jul 16.
2
Sterility Testing of Injectable Products: Evaluation of the Growth-based BacT/ALERT® 3D™ Dual T Culture System.
PDA J Pharm Sci Technol. 2016;70(6):568-576. doi: 10.5731/pdajpst.2016.006460. Epub 2016 Jun 20.
3
Evaluation of growth based rapid microbiological methods for sterility testing of vaccines and other biological products.
Vaccine. 2011 Oct 19;29(45):8012-23. doi: 10.1016/j.vaccine.2011.08.055. Epub 2011 Aug 24.
7
Application of the BacT/ALERTR 3D system for sterility testing of injectable products.
Braz J Microbiol. 2015 Jul 1;46(3):743-7. doi: 10.1590/S1517-838246320140587. eCollection 2015 Jul-Sep.
9
Bacterial contamination of platelet components not detected by BacT/ALERT.
Transfus Med. 2018 Feb;28(1):65-70. doi: 10.1111/tme.12458. Epub 2017 Sep 5.
10
Microbial surveillance during human pancreatic islet isolation.
Transpl Int. 2005 May;18(5):584-9. doi: 10.1111/j.1432-2277.2005.00092.x.

引用本文的文献

本文引用的文献

2
Incidence and clinical relevance of bacterial contamination in preservation solution for liver transplantation.
Transplant Proc. 2009 Jul-Aug;41(6):2169-71. doi: 10.1016/j.transproceed.2009.06.036.
4
Sterility testing of cell therapy products: parallel comparison of automated methods with a CFR-compliant method.
Transfusion. 2006 Dec;46(12):2071-82. doi: 10.1111/j.1537-2995.2006.01041.x.
5
Five-year follow-up after clinical islet transplantation.
Diabetes. 2005 Jul;54(7):2060-9. doi: 10.2337/diabetes.54.7.2060.
6
Microbial surveillance during human pancreatic islet isolation.
Transpl Int. 2005 May;18(5):584-9. doi: 10.1111/j.1432-2277.2005.00092.x.
7
Microbial surveillance during human pancreatic islet isolation.
Transplant Proc. 2004 May;36(4):1147-8. doi: 10.1016/j.transproceed.2004.04.025.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验