Suppr超能文献

环境温度纳米电喷雾离子淌度检测器在高效液相色谱法中用于测定胺类物质。

Ambient temperature nanoelectrospray ion mobility detector for high performance liquid chromatography in determining amines.

机构信息

Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, Liaoning, China.

Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, Liaoning, China.

出版信息

J Chromatogr A. 2014 Sep 5;1358:192-8. doi: 10.1016/j.chroma.2014.06.107. Epub 2014 Jul 21.

Abstract

A nanoelectrospray ionization ion mobility spectrometer (nanoESI-IMS) working at ambient pressure and ambient temperature was developed as a detector of high performance liquid chromatography (HPLC) to achieve sensitive detection of amines with no derivatization and meanwhile provide another dimension of separation. The easier desolvation property of the charged droplets formed in nanoESI source enabled complete desolvation of the product ions of sixteen amines and drugs using the nanoESI-IMS at ambient temperature. Working at ambient temperature was good for suppressing the dissociation of thermal volatile ions, such as only the proton adducted molecular ions were observed for morphine in the nanoESI-IMS. Besides, the resolving power of the nanoESI-IMS also showed an increasing tendency as lowering the working temperature, an increment of 19 percent and 10 percent was observed for diethylamine and triethylamine as the temperature dropped from 92°C to 32°C. The resolving power of the nanoESI-IMS at 32°C for the 16 tested compounds was amid 33-44. With the nanoESI-IMS coupled to HPLC, a six-compound mixture including isomers was successfully separated and detected without any derivatization. And linear response ranges of 1 to 20, 0.5 to 20, and 0.8 to 20μgml(-1) and limits of detection of 0.25, 0.15, and 0.17μgml(-1) for triethylamine, diethylamine, and butylamine, respectively, were obtained with the hyphenated system. These results showed the excellent performance of the two-dimensional separation and detection method in direct qualitative and quantitative analyses of amines.

摘要

一种在大气压和室温下工作的纳升电喷雾离子迁移谱(nanoESI-IMS)被开发为高效液相色谱(HPLC)的检测器,以实现对胺类物质的灵敏检测,无需衍生化,同时提供另一个分离维度。在纳升电喷雾源中形成的带电液滴更容易去溶剂化,因此可以在室温下使用 nanoESI-IMS 完全去溶剂化十六种胺类物质和药物的产物离子。在室温下工作有利于抑制热挥发性离子的解离,例如在 nanoESI-IMS 中仅观察到吗啡的质子加合分子离子。此外,随着工作温度的降低,nanoESI-IMS 的分辨力也呈现出增加的趋势,二乙胺和三乙胺的分辨力分别增加了 19%和 10%,当温度从 92°C 降至 32°C 时。在 32°C 下,nanoESI-IMS 对 16 种测试化合物的分辨力在 33-44 之间。将 nanoESI-IMS 与 HPLC 联用,无需衍生化即可成功分离和检测六种包括异构体在内的混合物。并且,在该联用系统中,三乙胺、二乙胺和正丁胺的线性响应范围分别为 1-20μgml(-1)、0.5-20μgml(-1)和 0.8-20μgml(-1),检测限分别为 0.25μgml(-1)、0.15μgml(-1)和 0.17μgml(-1)。这些结果表明,二维分离和检测方法在胺类物质的直接定性和定量分析中具有优异的性能。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验