PET/CT工作人员的眼部剂量监测。

Eye dose monitoring of PET/CT workers.

作者信息

Walsh C, O'Connor U, O'Reilly G

机构信息

Department of Medical Physics, St James's Hospital, Dublin, Ireland.

出版信息

Br J Radiol. 2014 Oct;87(1042):20140373. doi: 10.1259/bjr.20140373. Epub 2014 Aug 11.

Abstract

OBJECTIVE

The objective of the study was to measure eye dose [Hp(3)] to workers in a busy positron emission tomography (PET)/CT centre. Doses were compared with the proposed new annual dose limit of 20 mSv.

METHODS

We used a newly designed dosemeter to measure eye dose [Hp(3)]. Eye dosemeters were worn with an adjustable headband, with the dosemeter positioned adjacent to the left eye. The whole-body dose was also recorded using electronic personal dosemeter (EPD® Mk2; Thermo Electron Corporation, Waltham, MA). Exposed staff included radiographers, nurses and healthcare assistants.

RESULTS

The radiographers received the highest exposure of the staff groups studied, with one radiographer receiving an exposure of 0.5 mSv over the 3-month survey period. The estimated maximum eye dose for 1 year is approximately 2 mSv. The numeric value for eye dose was compared with the numeric value for personal dose equivalent to see if one could be used as an indicator for the other. From our data, a conservative estimate of eye dose Hp(3) (mSv) can be made as being up to approximately twice the numeric value for whole-body dose [Hp(10)] (mSv).

CONCLUSION

Eye dose was found to be well within the new proposed annual limit at our PET/CT centre. Routine whole-body dose measurements may be a useful starting point for assessing whether eye dose monitoring should be prioritized in a PET facility.

ADVANCES IN KNOWLEDGE

Following the proposal of a reduced eye dose limit, this article provides new measurement data on staff eye doses for PET/CT workers.

摘要

目的

本研究的目的是测量一家繁忙的正电子发射断层扫描(PET)/CT中心工作人员的眼部剂量[Hp(3)]。将这些剂量与新提议的20 mSv年度剂量限值进行比较。

方法

我们使用一种新设计的剂量计来测量眼部剂量[Hp(3)]。眼部剂量计通过可调节的头带佩戴,剂量计位于左眼附近。还使用电子个人剂量计(EPD® Mk2;热电电子公司,马萨诸塞州沃尔瑟姆)记录全身剂量。受照人员包括放射技师、护士和医疗助理。

结果

在所研究的工作人员群体中,放射技师接受的照射量最高,一名放射技师在3个月的调查期内接受的照射量为0.5 mSv。估计的1年最大眼部剂量约为2 mSv。将眼部剂量的数值与个人剂量当量的数值进行比较,以查看其中一个是否可以用作另一个的指标。根据我们的数据,可以保守估计眼部剂量Hp(3)(mSv)高达全身剂量[Hp(10)](mSv)数值的两倍左右。

结论

在我们的PET/CT中心,发现眼部剂量远低于新提议的年度限值。常规的全身剂量测量可能是评估PET设施中是否应优先进行眼部剂量监测的一个有用起点。

知识进展

在提议降低眼部剂量限值之后,本文提供了关于PET/CT工作人员眼部剂量的新测量数据。

相似文献

1
Eye dose monitoring of PET/CT workers.
Br J Radiol. 2014 Oct;87(1042):20140373. doi: 10.1259/bjr.20140373. Epub 2014 Aug 11.
2
Eye lens dose in interventional cardiology.
Radiat Prot Dosimetry. 2015 Jul;165(1-4):289-93. doi: 10.1093/rpd/ncv051. Epub 2015 Mar 24.
3
A retrospective evaluation of radiation dose associated with low dose FDG protocols in whole-body PET/CT.
Australas Phys Eng Sci Med. 2012 Mar;35(1):49-53. doi: 10.1007/s13246-011-0119-8. Epub 2011 Dec 10.
5
OCCUPATIONAL DOSE ASSESSMENT IN INTERVENTIONAL CARDIOLOGY IN SERBIA.
Radiat Prot Dosimetry. 2016 Sep;170(1-4):279-83. doi: 10.1093/rpd/ncv439. Epub 2015 Oct 13.
6
Assessment of occupational radiation dose in interventional settings.
Med Lav. 2018 Feb 1;109(1):57-67. doi: 10.23749/mdl.v109i1.5753.
7
OCCUPATIONAL EYE LENS DOSE OVER SIX YEARS IN THE STAFF OF A US HIGH-VOLUME CANCER CENTER.
Radiat Prot Dosimetry. 2020 Dec 30;192(3):321-327. doi: 10.1093/rpd/ncaa187.
8
Nuclear medicine staff exposure to ionising radiation in F-FDG PET/CT practice: a preliminary retrospective study.
Arh Hig Rada Toksikol. 2021 Sep 28;72(3):216-224. doi: 10.2478/aiht-2021-72-3517.
9
Occupational radiation exposure of health professionals and cancer risk assessment for Lithuanian nuclear medicine workers.
Environ Res. 2020 Apr;183:109144. doi: 10.1016/j.envres.2020.109144. Epub 2020 Jan 18.
10
Radiation exposure to nuclear medicine staff involved in PET/CT practice in Serbia.
Radiat Prot Dosimetry. 2014 Dec;162(4):577-85. doi: 10.1093/rpd/ncu001. Epub 2014 Jan 23.

引用本文的文献

1
Determination of a reliable assessment for occupational eye lens dose in nuclear medicine.
J Appl Clin Med Phys. 2022 Aug;23(8):e13713. doi: 10.1002/acm2.13713. Epub 2022 Jul 1.
2
ESTIMATION OF HP(3) AMONG STAFF MEMBERS IN TWO NUCLEAR MEDICINE UNITS IN FINLAND.
Radiat Prot Dosimetry. 2020 Aug 28;190(2):176-184. doi: 10.1093/rpd/ncaa096.
3
Effective and equivalent dose minimization for personnel in PET procedures: how far are we from the goal?
Eur J Nucl Med Mol Imaging. 2016 Dec;43(13):2279-2282. doi: 10.1007/s00259-016-3513-3.

本文引用的文献

2
Is the new ICRP eye dose limit justified?
J Radiol Prot. 2011 Dec;31(4):499-500. doi: 10.1088/0952-4746/31/4/L01. Epub 2011 Nov 17.
3
A 20 mSv dose limit for the eye: sense or no sense?
J Radiol Prot. 2011 Dec;31(4):385-7. doi: 10.1088/0952-4746/31/4/E03. Epub 2011 Nov 17.
5
Eye lens dosimetry: task 2 within the ORAMED project.
Radiat Prot Dosimetry. 2011 Mar;144(1-4):473-7. doi: 10.1093/rpd/ncr011. Epub 2011 Feb 20.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验