The objective of the study was to measure eye dose [Hp(3)] to workers in a busy positron emission tomography (PET)/CT centre. Doses were compared with the proposed new annual dose limit of 20 mSv.
We used a newly designed dosemeter to measure eye dose [Hp(3)]. Eye dosemeters were worn with an adjustable headband, with the dosemeter positioned adjacent to the left eye. The whole-body dose was also recorded using electronic personal dosemeter (EPD® Mk2; Thermo Electron Corporation, Waltham, MA). Exposed staff included radiographers, nurses and healthcare assistants.
The radiographers received the highest exposure of the staff groups studied, with one radiographer receiving an exposure of 0.5 mSv over the 3-month survey period. The estimated maximum eye dose for 1 year is approximately 2 mSv. The numeric value for eye dose was compared with the numeric value for personal dose equivalent to see if one could be used as an indicator for the other. From our data, a conservative estimate of eye dose Hp(3) (mSv) can be made as being up to approximately twice the numeric value for whole-body dose [Hp(10)] (mSv).
Eye dose was found to be well within the new proposed annual limit at our PET/CT centre. Routine whole-body dose measurements may be a useful starting point for assessing whether eye dose monitoring should be prioritized in a PET facility.
Following the proposal of a reduced eye dose limit, this article provides new measurement data on staff eye doses for PET/CT workers.
本研究的目的是测量一家繁忙的正电子发射断层扫描(PET)/CT中心工作人员的眼部剂量[Hp(3)]。将这些剂量与新提议的20 mSv年度剂量限值进行比较。
我们使用一种新设计的剂量计来测量眼部剂量[Hp(3)]。眼部剂量计通过可调节的头带佩戴,剂量计位于左眼附近。还使用电子个人剂量计(EPD® Mk2;热电电子公司,马萨诸塞州沃尔瑟姆)记录全身剂量。受照人员包括放射技师、护士和医疗助理。
在所研究的工作人员群体中,放射技师接受的照射量最高,一名放射技师在3个月的调查期内接受的照射量为0.5 mSv。估计的1年最大眼部剂量约为2 mSv。将眼部剂量的数值与个人剂量当量的数值进行比较,以查看其中一个是否可以用作另一个的指标。根据我们的数据,可以保守估计眼部剂量Hp(3)(mSv)高达全身剂量[Hp(10)](mSv)数值的两倍左右。
在我们的PET/CT中心,发现眼部剂量远低于新提议的年度限值。常规的全身剂量测量可能是评估PET设施中是否应优先进行眼部剂量监测的一个有用起点。
在提议降低眼部剂量限值之后,本文提供了关于PET/CT工作人员眼部剂量的新测量数据。