Suppr超能文献

核医学工作人员在 F-FDG PET/CT 实践中接触电离辐射:一项初步回顾性研究。

Nuclear medicine staff exposure to ionising radiation in F-FDG PET/CT practice: a preliminary retrospective study.

机构信息

Center for Radiation Therapy, International Medical Centers, Affidea, Banja Luka, Bosnia and Herzegovina.

University of Novi Sad Faculty of Sciences, Novi Sad, Serbia.

出版信息

Arh Hig Rada Toksikol. 2021 Sep 28;72(3):216-224. doi: 10.2478/aiht-2021-72-3517.

Abstract

This retrospective study provides an insight into the levels of radiation exposure of six nuclear medicine (NM) staff (four technologists and two nurses) performing routine diagnostic F-fluorodeoxyglucose (F-FDG) positron emission tomography-computed tomography (PET/CT) at the University Clinical Centre of the Republic of Srpska, Department of Nuclear Medicine and Thyroid Disorders, Banja Luka, Bosnia and Herzegovina. Data analysis included monthly staff exposure measured with personal thermoluminescent dosimeters (TLD) between June and December 2018, quantified in terms of normalised dose for the whole body [Hp(10)] and dominant hand [Hp(0.07)] and their comparison between each staff member and between the two groups (technologists and nurses). The study goal was to establish how our Department compared with reports from other PET/CT centres worldwide in terms of annual number of procedures and exposure limits and whether there could be room for further improvements in radiation protection. The number of procedures rose considerably from 208 in 2016 to 876 in 2019 and was 423 in the observed seven-month period. Mean individual whole-body exposure dose per GBq of injected F-FDG activity, [Hp(10)/A] was 18.55 μSv/GBq for the four technologists and 15.61 μSv/GBq for the two nurses. Mean dominant-hand exposure dose per GBq of injected F-FDG activity [Hp(0.07)/A] was 16.99 μSv/GBq and 25.44 μSv/GBq for the two groups, respectively. The average annual cumulative dose for all staff was (1.06±0.29) mSv for Hp(10) and (1.15±0.32) mSv for Hp(0.07). These results are comparable with those of similar studies. Staff doses were well below the annual limits. Nurses received slightly higher extremity doses than technologists. In view of the increasing trends in the number of PET/CT procedures, dose monitoring should be continued to identify exposure hotspots and maintain doses as low as possible.

摘要

这项回顾性研究深入探讨了 6 名核医学(NM)工作人员(4 名技术员和 2 名护士)在波黑塞族共和国巴尼亚卢卡大学临床中心核医学和甲状腺疾病系进行常规诊断 F-氟代脱氧葡萄糖(F-FDG)正电子发射断层扫描-计算机断层扫描(PET/CT)时的辐射暴露水平。数据分析包括 2018 年 6 月至 12 月期间使用个人热释光剂量计(TLD)每月测量的工作人员暴露量,以全身归一剂量[Hp(10)]和优势手[Hp(0.07)]来量化,并对每个工作人员之间以及两组(技术员和护士)之间进行了比较。研究目的是确定我们的部门在每年的程序数量和辐射暴露限值方面与全球其他 PET/CT 中心的报告相比如何,以及在辐射防护方面是否有进一步改进的空间。从 2016 年的 208 例到 2019 年的 876 例,程序数量显著增加,在观察的七个月期间为 423 例。每位工作人员每注射 1GBq F-FDG 活性的个体全身平均暴露剂量[Hp(10)/A]为 4 名技术员的 18.55 μSv/GBq 和 2 名护士的 15.61 μSv/GBq。每位工作人员每注射 1GBq F-FDG 活性的优势手平均暴露剂量[Hp(0.07)/A]分别为 16.99 μSv/GBq 和 25.44 μSv/GBq。所有工作人员的平均年累积剂量为 Hp(10)为(1.06±0.29)mSv,Hp(0.07)为(1.15±0.32)mSv。这些结果与类似研究相当。工作人员的剂量远低于年限制。护士接受的四肢剂量略高于技术员。鉴于 PET/CT 程序数量的增加趋势,应继续进行剂量监测,以确定暴露热点并尽可能保持剂量最低。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1990/8576747/142168676525/aiht-72-216-g001.jpg