Agarwal Shweta, Vargas German, Nordstrom Cristina, Tam Estella, Buffone Gregory J, Devaraj Sridevi
Department of Pathology & Immunology, Baylor College of Medicine and Texas Children's Hospital, Houston, TX 77030, USA.
Department of Pathology & Immunology, Baylor College of Medicine and Texas Children's Hospital, Houston, TX 77030, USA.
Clin Chim Acta. 2015 Jan 1;438:241-5. doi: 10.1016/j.cca.2014.08.008. Epub 2014 Aug 13.
Clinical laboratory assays can be affected by interferents like hemoglobin (Hb), lipids and bilirubin. We evaluated the effect of these interferences on pediatric samples for different chemistry assays. Further we established cut-off indices above which these interferences confound sample results.
Three separate serum pools were spiked with increasing concentrations of hemolysate or intralipid or bilirubin and different analytes were analyzed. The Hemolysis-(H), Lipemia-(T) and Icterus-(I) indices were measured on Vitros 5600. Analytes affected by lipemia were treated with LipoClear ® and re-analyzed. All the measured analytes were compromised by gross hemolysis (H-Index >1000).
Except lipase and magnesium (Mg(++)), all other analytes were affected by moderate (H-Index >250) and significant hemolysis (H-Index >500). Low estradiol levels showed a significant effect at severe icterus (I-Index >20.0). C3, C4, Ceruloplasmin, Haptoglobin, Immunoglobulins (Ig) and Vitamin D were significantly affected by moderate (T-Index >100) and severe (T-Index >500) lipemia. LipoClear ® treatment significantly attenuated the lipemic interference on the above analytes except for C3, C4, and IgG.
Accurate reporting of pediatric samples for the analytes affected by common interferences will lead to better clinical interpretation.
临床实验室检测可能会受到血红蛋白(Hb)、脂质和胆红素等干扰物的影响。我们评估了这些干扰对儿科样本不同化学检测的影响。此外,我们确定了干扰会混淆样本结果的临界指数。
向三个单独的血清混合液中加入浓度递增的溶血产物、脂肪乳剂或胆红素,然后分析不同的分析物。在Vitros 5600上测量溶血(H)指数、脂血(T)指数和黄疸(I)指数。受脂血影响的分析物用LipoClear®处理后重新分析。所有测量的分析物都受到严重溶血(H指数>1000)的影响。
除脂肪酶和镁(Mg(++))外,所有其他分析物都受到中度溶血(H指数>250)和显著溶血(H指数>500)的影响。低雌二醇水平在严重黄疸(I指数>20.0)时显示出显著影响。补体C3、C4、铜蓝蛋白、触珠蛋白、免疫球蛋白(Ig)和维生素D受到中度脂血(T指数>100)和重度脂血(T指数>500)的显著影响。LipoClear®处理显著减轻了脂血对上述分析物的干扰,但对C3、C4和IgG除外。
对于受常见干扰影响的分析物,准确报告儿科样本将有助于更好地进行临床解读。