Suppr超能文献

比较数字化根尖片与锥形束计算机断层扫描在检测垂直根折方面的体内诊断准确性。

Comparing the in vivo diagnostic accuracy of digital periapical radiography with cone-beam computed tomography for the detection of vertical root fracture.

作者信息

Chavda Rajesh, Mannocci Francesco, Andiappan Manoharan, Patel Shanon

机构信息

Department of Endodontology, Kings College Dental Institute, London, United Kingdom.

Biomedical Statistics, Dental Institute, Denmark Hill, London, United Kingdom.

出版信息

J Endod. 2014 Oct;40(10):1524-9. doi: 10.1016/j.joen.2014.05.011. Epub 2014 Aug 22.

Abstract

INTRODUCTION

The purpose of this study was to determine whether there is a difference in the in vivo diagnostic accuracy of digital radiography (DR) and cone-beam computed tomography (CBCT) imaging in the detection of vertical root fracture (VRF). The presence/absence of VRF was confirmed by visual inspection of the extracted root surface and was the reference standard against which both imaging modalities were compared.

METHODS

Twenty-one unsalvageable teeth from 20 patients that had been radiographed and scanned with CBCT imaging were included in the study. The teeth were atraumatically extracted and visually inspected under a microscope to confirm the presence/absence of fracture. The widest point of each fracture was recorded using an optical coherence tomography scanner in order to quantify the size of fractures. Images were viewed under standardized conditions by 13 examiners and repeated 2 weeks later to assess their consistency.

RESULTS

DR and CBCT imaging showed similarly poor sensitivity of 0.16 and 0.27, respectively. Both imaging modalities had similarly high specificity of 0.92 and 0.83, respectively. There was no statistical difference between the diagnostic accuracy of either imaging modality. Fracture width did not affect the detection rate of either imaging modality. Receiver operating characteristic analysis revealed mean Az values of 0.535 and 0.552 for DR and CBCT imaging, respectively.

CONCLUSIONS

Both DR and CBCT imaging have significant limitations when detecting vertical root fractures.

摘要

引言

本研究的目的是确定数字X线摄影(DR)和锥形束计算机断层扫描(CBCT)成像在检测垂直根折(VRF)方面的体内诊断准确性是否存在差异。通过对拔除牙根表面的目视检查来确认VRF的存在与否,并将其作为两种成像方式比较的参考标准。

方法

本研究纳入了20例患者的21颗无法保留的牙齿,这些牙齿已进行CBCT成像的X线摄影和扫描。牙齿在无创伤情况下拔除,并在显微镜下进行目视检查以确认是否存在骨折。使用光学相干断层扫描扫描仪记录每个骨折的最宽点,以量化骨折的大小。13名检查人员在标准化条件下查看图像,并在2周后重复查看以评估其一致性。

结果

DR和CBCT成像的敏感性分别同样较差,为0.16和0.27。两种成像方式的特异性分别同样较高,为0.92和0.83。两种成像方式的诊断准确性之间没有统计学差异。骨折宽度不影响任何一种成像方式的检测率。受试者工作特征分析显示,DR和CBCT成像的平均Az值分别为0.535和0.552。

结论

在检测垂直根折时,DR和CBCT成像都有显著局限性。