PURPOSE. To evaluate the outcome of percutaneous release of the A1 pulley in 40 cadaveric fingers using a modified Kirschner wire. METHODS. A 2.5-mm-diameter Kirschner wire measuring >12 cm in length was used. One end of the wire was sharpened into a 'J' shape using a grinder. The J-shaped tip featured a blunt, elongated lower tip, a sharp J-shaped curve, and a blunt upper tip. Completeness of A1 pulley release and injuries to the A2 pulley, flexor tendon, and neurovascular structures were evaluated in 40 cadaveric fingers. RESULTS. Complete release of the A1 pulley was achieved in 8 index, 7 middle, 8 ring, and 8 little fingers, whereas incomplete release of the distal part was noted in 2 index, 2 middle, 2 ring, and one little fingers; release was missed in one middle and one little fingers. Injury to the A2 pulley was noted in 2 index fingers; the injury was minimal and limited to the proximal 2 mm of the A2 pulley. There was no flexor tendon or digital nerve injury in any finger. CONCLUSION. Percutaneous release of the A1 pulley using a modified Kirschner wire achieved complete release in 78% of cadaveric fingers, which is comparable to that using a specially manufactured push knife.
目的。使用改良克氏针评估40个尸体手指经皮松解A1滑车的结果。方法。使用一根直径2.5毫米、长度大于12厘米的克氏针。用磨床将针的一端磨成“J”形。“J”形尖端有一个钝的、细长的下端,一个尖锐的“J”形曲线,以及一个钝的上端。在40个尸体手指中评估A1滑车松解的完整性以及对A2滑车、屈肌腱和神经血管结构的损伤。结果。在8个示指、7个中指、8个环指和8个小指中实现了A1滑车的完全松解,而在2个示指、2个中指、2个环指和1个小指中发现远端部分松解不完全;在1个中指和1个小指中松解未成功。在2个示指中发现A2滑车损伤;损伤轻微,仅限于A2滑车近端2毫米。任何手指均未出现屈肌腱或指神经损伤。结论。使用改良克氏针对A1滑车进行经皮松解,在78%的尸体手指中实现了完全松解,这与使用特制推刀的效果相当。