Suppr超能文献

使用脉冲-连续动脉自旋标记和单光子发射计算机断层扫描获取的定量灌注图的无操作者偏差比较。

Operator-bias-free comparison of quantitative perfusion maps acquired with pulsed-continuous arterial spin labeling and single-photon-emission computed tomography.

作者信息

Iwanaga Takashi, Harada Masafumi, Kubo Hitoshi, Funakoshi Yasuhiro, Kunikane Yamato, Matsuda Tsuyoshi

机构信息

Department of Medical Imaging, Institute of Health Biosciences, The University of Tokushima Graduate School.

出版信息

Magn Reson Med Sci. 2014;13(4):239-49. doi: 10.2463/mrms.2013-0117. Epub 2014 Aug 27.

Abstract

PURPOSE

We compared the regional cerebral blood flow (rCBF) obtained by pulsed continuous arterial spin labeling (pCASL) and iodine-123-N-isopropyl-p-iodoamphetamine (IMP) single photon emission computed tomography (SPECT) using 3-dimensional stereotactic region-of-interest (ROI) software for automated definition of ROIs in anatomic regions of the brain.

METHODS

Thirteen patients with cerebrovascular occlusive disease and three with transient ischemic attacks underwent pCASL and IMP SPECT imaging. We compared rCBF values of each anatomic region and calculated the correlation coefficients between pCASL and IMP SPECT. We also calculated the asymmetry index (AI) using ROIs in contralateral regions of the hemispheres.

RESULTS

The rCBF values calculated from pCASL and IMP SPECT were comparable in most segments, but rCBF in the thalamus (P < 0.0001) and hippocampus (P = 0.0006) was significantly higher measured by pCASL than IMP SPECT. The correlation of rCBF between pCASL and IMP SPECT in the affected hemisphere (r = 0.50) tended to be lower than that in the normal hemisphere (r = 0.59), but not significantly different (P = 0.25). Moreover, there was a fixed bias for underestimation of rCBF by pCASL (P = 0.0047) in the affected hemisphere. The calculated AI showed a significant relationship between methods (r = 0.79, P < 0.0001).

CONCLUSION

The rCBF obtained by pCASL had positive relationships with IMP SPECT. However, it should be considered that pCASL tends to have a weak relationship with IMP SPECT in some normal regions and regions affected by cerebrovascular occlusive disease.

摘要

目的

我们使用三维立体定向感兴趣区(ROI)软件自动定义脑解剖区域的ROI,比较了脉冲连续动脉自旋标记(pCASL)和碘-123-N-异丙基-p-碘安非他明(IMP)单光子发射计算机断层扫描(SPECT)获得的局部脑血流量(rCBF)。

方法

13例脑血管闭塞性疾病患者和3例短暂性脑缺血发作患者接受了pCASL和IMP SPECT成像。我们比较了每个解剖区域的rCBF值,并计算了pCASL和IMP SPECT之间的相关系数。我们还使用半球对侧区域的ROI计算了不对称指数(AI)。

结果

pCASL和IMP SPECT计算的rCBF值在大多数节段中具有可比性,但pCASL测量的丘脑(P < 0.0001)和海马(P = 0.0006)的rCBF明显高于IMP SPECT。患侧半球pCASL和IMP SPECT的rCBF相关性(r = 0.50)往往低于正常半球(r = 0.59),但差异无统计学意义(P = 0.25)。此外,患侧半球pCASL对rCBF的低估存在固定偏差(P = 0.0047)。计算出的AI显示方法之间存在显著关系(r = 0.79,P < 0.0001)。

结论

pCASL获得的rCBF与IMP SPECT呈正相关。然而,应该考虑到,在一些正常区域和受脑血管闭塞性疾病影响的区域,pCASL与IMP SPECT的关系往往较弱。