Abstract

Finite element (FE) filtering facepiece respirators (FFRs) were developed and mated to the new headforms with a cervical spine model. The FFRs from three manufacturers included three sizing systems: (i) a single one-size-fits all, (ii) an FFR with two sizes (S/M and M/L), and (iii) an FFR with three sizes (S, L/M, XL). Finite element method (FEM) simulations of 16 headform and respirator combinations (5 headforms and 6 respirators) were used to examine maximum contact pressure changes for five cases: static head, flexion, extension, left rotation, and right rotation. For each of the 16 headform and respirator combinations, maximum contact pressures of the static headform and motile headforms were compared using t-tests. Significant differences on the maximum contact pressures were found in the extension, left rotation and right rotation at the nose (P < 0.005), the left rotation at the top of right cheek (P = 0.03), and the extension at the bottom of left/right cheek (P = 0.01). When separately considering each headform and each FFR manufacturer, the effects of the four head movement cases on the nose maximum contact pressure changes were observed in the simulations with all five headforms and all FFR manufacturers. The effects of the left and right rotations on the chin maximum contact pressure changes were observed in the simulations with the small headform. It was also found that the use of a nose clip could reduce the impact of the head left/right rotations on nose maximum contact pressure changes. In addition, head movements changed pressure contours of the key nose area. Caused by the head movements, the maximum contact pressure changes may affect seal quality, and the increase of the maximum contact pressures could reduce the facial comfort level.

摘要

开发了有限元(FE)过滤式面罩呼吸器(FFR),并将其与带有颈椎模型的新型头模相匹配。来自三个制造商的FFR包括三种尺寸系统:(i)单一的均码尺寸,(ii)具有两种尺寸(S/M和M/L)的FFR,以及(iii)具有三种尺寸(S、L/M、XL)的FFR。使用有限元方法(FEM)对16种头模和呼吸器组合(5种头模和6种呼吸器)进行模拟,以检查五种情况下的最大接触压力变化:静态头部、前屈、后伸、左旋和右旋。对于16种头模和呼吸器组合中的每一种,使用t检验比较静态头模和活动头模的最大接触压力。发现在鼻子处的后伸、左旋和右旋(P<0.005)、右脸颊顶部的左旋(P = 0.03)以及左/右脸颊底部的后伸(P = 0.01)时,最大接触压力存在显著差异。当分别考虑每个头模和每个FFR制造商时,在所有五种头模和所有FFR制造商的模拟中都观察到了四种头部运动情况对鼻子最大接触压力变化的影响。在小头模的模拟中观察到左旋和右旋对下巴最大接触压力变化的影响。还发现使用鼻夹可以减少头部左右旋转对鼻子最大接触压力变化的影响。此外,头部运动改变了关键鼻子区域的压力轮廓。由头部运动引起的最大接触压力变化可能会影响密封质量,而最大接触压力的增加可能会降低面部舒适度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验