Gerhardt G A, Dwoskin L P, Zahniser N R
Department of Psychiatry, University of Colorado Health Sciences Center, Denver 80262.
J Neurosci Methods. 1989 Jan;26(3):217-27. doi: 10.1016/0165-0270(89)90119-2.
An improved method for the rapid and sensitive determination of endogenous dopamine (DA) and 3,4-dihydroxyphenylacetic acid (DOPAC) in superfusates of single rat striatal slices, using high-performance liquid chromatography (HPLC) coupled with 'coulometric' electrochemical detection (EC), is described. Superfusates are directly injected into an HPLC-EC system following addition of a small aliquot of solubilized ascorbate-oxidase. DA and DOPAC are both separated and quantitated in 3-5 min. Twelve to 15 samples can be analyzed each hour with a nominal detection limit of 1.0 pg per injection for each compound or 10-20 pg/ml of superfusate. The present method was used to study changes in DA and DOPAC outflow and overflow in superfusates of single striatal slices following electrical field stimulation, both in the absence and presence of the catecholamine uptake inhibitor nomifensine. Studies of 1 min superfusate collections clearly showed that electrical field stimulation produced a latent increase in DOPAC as compared to DA. The routine sensitivity and sample throughout of the method allows for studies of both outflow and overflow of DA and DOPAC, as well as studies involving time-dependent overflow of these compounds.
本文描述了一种改进的方法,用于使用高效液相色谱(HPLC)结合“库仑”电化学检测(EC)快速灵敏地测定大鼠单个纹状体切片灌流液中的内源性多巴胺(DA)和3,4-二羟基苯乙酸(DOPAC)。在加入一小份溶解的抗坏血酸氧化酶后,将灌流液直接注入HPLC-EC系统。DA和DOPAC均可在3-5分钟内分离并定量。每小时可分析12至15个样品,每种化合物每次进样的标称检测限为1.0 pg,或灌流液中为10-20 pg/ml。本方法用于研究在电场刺激下,无论有无儿茶酚胺摄取抑制剂诺米芬辛时,单个纹状体切片灌流液中DA和DOPAC流出和溢出的变化。对1分钟灌流液收集的研究清楚地表明,与DA相比,电场刺激使DOPAC产生潜在增加。该方法的常规灵敏度和样品通量允许对DA和DOPAC的流出和溢出进行研究,以及涉及这些化合物时间依赖性溢出的研究。