Schröter S, Ateschrang A, Ihle C, Stöckle U, Konstantinidis L, Döbele S
BG Unfallklinik Tübingen, Klinik für Unfall- und Wiederherstellungschirurgie, Eberhard Karls Universität Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Deutschland,
Orthopade. 2014 Nov;43(11):1000-7. doi: 10.1007/s00132-014-3026-3.
Open wedge high tibial osteotomy (HTO) is an increasingly more common surgical method. A typical problem of this procedure is fracture of the lateral hinge.
The aims of this article are to present the special issue of fractures of the lateral hinge after HTO and to discuss surgical hints on how to prevent and treat this problem.
The results of recently published clinical studies are summarized and tips from own clinical experiences are given.
Type II fractures of the lateral hinge are unstable and can create a major problem. Using short spacer plates results in a problem of stability for all types of fractures.
The classification into Takeuchi grades I-III has been proven to be suitable for fractures of the lateral hinge. The TomoFix plate is a safe implant to stabilize the osteotomy in type I and III fractures with which healing can be achieved with no problems. Type II fractures can be stabilized with the TomoFix plate; however, an autologous bone graft has to be taken into consideration. For fractures of the lateral hinge short spacer plates are not recommended due to stability issues.
开放楔形高位胫骨截骨术(HTO)是一种越来越常见的手术方法。该手术的一个典型问题是外侧铰链骨折。
本文旨在介绍HTO术后外侧铰链骨折的特殊问题,并讨论如何预防和治疗该问题的手术要点。
总结近期发表的临床研究结果,并给出自身临床经验的提示。
外侧铰链的II型骨折不稳定,可能会造成重大问题。使用短间隔钢板会导致各类骨折的稳定性问题。
已证明将外侧铰链骨折分为竹内I-III级是合适的。TomoFix钢板是一种安全的植入物,可稳定I型和III型骨折的截骨,骨折愈合不会有问题。II型骨折可用TomoFix钢板稳定;然而,必须考虑自体骨移植。由于稳定性问题,不建议使用短间隔钢板治疗外侧铰链骨折。