Olesen H P, Sjøntoft E, Tronier B
Institute for Experimental Research in Surgery, University of Copenhagen, Denmark.
Lab Anim Sci. 1989 Sep;39(5):429-32.
A surgical model for catheterization at multiple sites has been developed for use in long-term metabolic studies. For blood sampling, catheters were inserted into the portal and hepatic veins and the common carotid artery. The hepatic vein catheter was inserted from the margin of a liver lobe and led through the venous system, until the tip was close to the bifurcation with the inferior vena cava. A new technique was developed to ensure correct placement of the hepatic vein catheter using the specific extraction of indocyanin-green over the liver during surgery. Gastrostomy was performed using a Pezzer catheter. Catheters in the artery and hepatic and portal veins were patent for blood withdrawal for up to 4 weeks, and thus allowed repeated metabolic studies. Studies were performed in conscious animals familiar with the experimental situation.
已开发出一种用于多部位插管的手术模型,用于长期代谢研究。为了进行血液采样,将导管插入门静脉、肝静脉和颈总动脉。肝静脉导管从肝叶边缘插入,穿过静脉系统,直到尖端靠近与下腔静脉的分叉处。开发了一种新技术,通过在手术期间对肝脏进行吲哚菁绿的特异性提取来确保肝静脉导管的正确放置。使用Pezzer导管进行胃造口术。动脉、肝静脉和门静脉中的导管在长达4周的时间内可用于采血,因此可以进行重复的代谢研究。研究在熟悉实验环境的清醒动物身上进行。