Dubuisson Olga, Day Rena Sue, Dhurandhar Nikhil V
Infections and Obesity Laboratory, Pennington Biomedical Research Center, Baton Rouge, LA 70808 USA.
Michael & Susan Dell Center for Healthy Living The University of Texas School of Public Health, Houston, TX 77030 USA.
J Diabetes Complications. 2015 Jan-Feb;29(1):83-7. doi: 10.1016/j.jdiacomp.2014.09.004. Epub 2014 Sep 16.
In children and adults, human adenovirus serotype 36 (Ad36) is linked with increased adiposity, and important metabolic alterations. Since this property is not shared by many other human adenovirus serotypes, it is imperative to specifically identify exposure to Ad36. Although serum neutralization assay (SNA) is the gold standard to specifically detect neutralizing antibodies (NA) to Ad36, it requires 2-weeks to complete and considerable training to interpret the results. Whereas, an enzyme-immuno assay (EIA) may provide a quicker and objective determination.
Evaluate the accuracy of commercially available EIA kits to detect NA to Ad36. Modify SNA to reduce time and increase objectivity.
Sera of 15 seropositive or 16 seronegative subjects confirmed by SNA were used to test: 1) reproducibility of SNA to detect Ad36 exposure, by repeating assays twice; 2) an EIA that detects antibodies to all human adenovirus serotypes (NS-EIA) (Abcam-108705); 3) an EIA supposedly specific for Ad36 antibody (Ad36-EIA) (MyBioSource,#MBS705802), and 4) the concordance of SNA with a novel combination of SNA and immune-staining (SN-IS) kit (Cell BioLabs,#VPK-111).
The SNA showed exact reproducibility. NS-EIA detected adenovirus antibodies in 94% samples, confirming the non-specificity of the assay for Ad36 serotype. All seronegative samples (as determined by SNA) were false positive by Ad36-EIA. In 97% samples, SN-IS showed fidelity with Ad36-antibody status as determined by SNA.
The available EIA kits are not specific for detecting NA to Ad36. The modified SNA with immune-staining reduces assay time and increases accuracy of detecting by reducing subjectivity.
在儿童和成人中,人腺病毒36型(Ad36)与肥胖增加及重要的代谢改变有关。由于许多其他人类腺病毒血清型不具备这一特性,因此必须专门确定是否接触过Ad36。虽然血清中和试验(SNA)是特异性检测针对Ad36的中和抗体(NA)的金标准,但它需要两周时间才能完成,且解读结果需要大量培训。而酶免疫测定(EIA)可能会提供更快速、客观的检测结果。
评估市售EIA试剂盒检测针对Ad36的NA的准确性。对SNA进行改进以减少检测时间并提高客观性。
使用经SNA确认的15名血清阳性或16名血清阴性受试者的血清来检测:1)通过重复检测两次来评估SNA检测Ad36暴露的可重复性;2)一种检测所有人类腺病毒血清型抗体的EIA(NS-EIA)(Abcam-108705);3)一种据称对Ad36抗体具有特异性的EIA(Ad36-EIA)(MyBioSource,#MBS705802);4)SNA与SNA和免疫染色(SN-IS)试剂盒(Cell BioLabs,#VPK-111)新组合的一致性。
SNA显示出确切的可重复性。NS-EIA在94%的样本中检测到腺病毒抗体,证实了该检测方法对Ad36血清型的非特异性。所有血清阴性样本(由SNA确定)经Ad36-EIA检测均为假阳性。在97%的样本中,SN-IS显示与SNA确定的Ad36抗体状态相符。
现有的EIA试剂盒并非特异性检测针对Ad36的NA。改进后的带有免疫染色的SNA减少了检测时间,并通过降低主观性提高了检测准确性。