Suppr超能文献

使用新开发的广域近红外成像系统(Compovision)对聚乳酸光降解过程中的结晶度变化进行高速监测。

High-speed monitoring of the crystallinity change in poly(lactic acid) during photodegradation by using a newly developed wide area NIR imaging system (Compovision).

作者信息

Ishikawa Daitaro, Furukawa Daiki, Wei Tseng Tsai, Reddy Kummetha Raghunatha, Motomura Asako, Igarashi Yoko, Sato Harumi, Kazarian Sergei G, Ozaki Yukihiro

机构信息

Graduate School of Agriculture, Tohoku University, 1-1, Amamiya, Tsutumidori, Aoba-ku, Sendai, 981-8555, Japan,

出版信息

Anal Bioanal Chem. 2015 Jan;407(2):397-403. doi: 10.1007/s00216-014-8211-z. Epub 2014 Oct 19.

Abstract

We aimed to achieve wide area rapid monitoring of the crystallinity change in poly(lactic acid) (PLA) during photodegradation caused by ultraviolet (UV) light by using a newly developed near-infrared (NIR) camera (Compovison). Several kinds of PLA samples with different crystallinities and their blends with poly[(3)-(R)-hydroxybutyrate] were prepared. Their two-dimensional NIR spectra in the 1,000-2,350-nm region were measured by Compovision at a 5-min interval during photolysis. An intensity decrease of the band in the 1,900-1,925-nm region due to the second overtone of the C = O stretching vibration of PLA was observed during photolysis. This suggests that an anhydride carbonyl is produced during photolysis. The NIR image of the crystallinity change monitored by the band at 1,917 nm in the standard normal variate spectra clearly shows the inhomogeneity of crystal evolution. A logarithmic increase was observed for all identified areas in the PLA film; however, the time to reach the maximum crystallinity was slightly different according to the initial crystallinity of the sample. It is likely that the initial crystallinity of the sample influences the degradation speed more than the degradation amount. These imaging results have provided fundamental chemical insights into the photolytic process for PLA, and at the same time they have demonstrated that the two-dimensional spectral data obtained by Compovision are useful for process monitoring of polymers.

摘要

我们旨在通过使用新开发的近红外(NIR)相机(Compovison),对聚乳酸(PLA)在紫外(UV)光引起的光降解过程中的结晶度变化进行大面积快速监测。制备了几种具有不同结晶度的PLA样品及其与聚[(3)-(R)-羟基丁酸酯]的共混物。在光解过程中,Compovision以5分钟的间隔测量了它们在1000-2350nm区域的二维近红外光谱。在光解过程中,观察到由于PLA的C=O伸缩振动的二次泛音导致的1900-1925nm区域的谱带强度下降。这表明在光解过程中产生了酸酐羰基。在标准正态变量光谱中,由1917nm谱带监测的结晶度变化的近红外图像清楚地显示了晶体演化的不均匀性。在PLA薄膜的所有识别区域都观察到对数增加;然而,根据样品的初始结晶度,达到最大结晶度的时间略有不同。样品的初始结晶度可能比降解量对降解速度的影响更大。这些成像结果为PLA的光解过程提供了基本的化学见解,同时也证明了由Compovision获得的二维光谱数据可用于聚合物的过程监测。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验