From the Department of Adult Critical Care Medicine, King Khalid University Hospital, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
From the Department of Adult Critical Care Medicine, King Khalid University Hospital, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
Chest. 2014 Nov;146(5):e160-e162. doi: 10.1378/chest.14-0411.
A 70-year-old man underwent total hip replacement surgery under general anesthesia, endotracheal intubation, and controlled ventilation, with the patient in left lateral position. Intraoperatively, the patient was hemodynamically stable, with a normal range of pulse, ECG trace, oxygen saturation as measured by pulse oximetry (Spo2), and end-tidal CO2 (etco2). Five minutes after insertion of the hip prosthesis, his heart rate dropped to 30 beats/min, BP to 40/30 mm Hg, Spo2 to 70%, and etco2 to 10 mm Hg.
一位 70 岁男性在全身麻醉、气管插管和控制通气下接受了全髋关节置换手术,患者处于左侧卧位。术中患者血流动力学稳定,脉搏、心电图轨迹、脉搏血氧饱和度(SpO2)和呼气末二氧化碳(etCO2)均在正常范围内。在插入髋关节假体后 5 分钟,他的心率降至 30 次/分,血压降至 40/30 mmHg,SpO2 降至 70%,etCO2 降至 10 mmHg。