Suppr超能文献

准分子激光原位角膜磨镶术后患者人工晶状体植入的角膜前表面屈光力计算

Corneal Anterior Power Calculation for an IOL in Post-PRK Patients.

作者信息

De Bernardo Maddalena, Iaccarino Stefania, Cennamo Michela, Caliendo Luisa, Rosa Nicola

机构信息

*MD Department of Medicine and Surgery, University of Salerno, Salerno, Italy (all authors).

出版信息

Optom Vis Sci. 2015 Feb;92(2):190-5. doi: 10.1097/OPX.0000000000000458.

Abstract

PURPOSE

After corneal refractive surgery, there is an overestimation of the corneal power with the devices routinely used to measure it. Therefore, the objective of this study was to determine whether, in patients who underwent photorefractive keratectomy (PRK), it is possible to predict the earlier preoperative anterior corneal power from the postoperative (PO) posterior corneal power. A comparison is made using a formula published by Saiki for laser in situ keratomileusis patients and a new one calculated specifically from PRK patients.

METHODS

The Saiki formula was tested in 98 eyes of 98 patients (47 women) who underwent PRK for myopia or myopic astigmatism. Moreover, anterior and posterior mean keratometry (Km) values from a Scheimpflug camera were measured to obtain a specific regression formula.

RESULTS

The mean (±SD) preoperative Km was 43.50 (±1.39) diopters (D) (range, 39.25 to 47.05 D). The mean (±SD) Km value calculated with the Saiki formula using the 6 months PO posterior Km was 42.94 (±1.19) D (range, 40.34 to 45.98 D) with a statistically significant difference (p < 0.001). Six months after PRK in our patients, the posterior Km was correlated with the anterior preoperative one by the following regression formula: y = -4.9707x + 12.457 (R² = 0.7656), where x is PO posterior Km and y is preoperative anterior Km, similar to the one calculated by Saiki.

CONCLUSIONS

Care should be taken in using the Saiki formula to calculate the preoperative Km in patients who underwent PRK.

摘要

目的

角膜屈光手术后,常规用于测量角膜屈光力的设备会高估角膜屈光力。因此,本研究的目的是确定在接受准分子激光角膜切削术(PRK)的患者中,是否可以根据术后(PO)的后表面角膜屈光力预测术前较早时间的前表面角膜屈光力。使用斋木为激光原位角膜磨镶术患者发表的公式与专门根据PRK患者计算的新公式进行比较。

方法

对98例(47例女性)因近视或近视散光接受PRK的患者的98只眼进行斋木公式测试。此外,使用角膜地形图仪测量前、后平均角膜曲率(Km)值,以获得特定的回归公式。

结果

术前平均(±标准差)Km为43.50(±1.39)屈光度(D)(范围为39.25至47.05 D)。使用斋木公式根据术后6个月的后表面Km计算的平均(±标准差)Km值为42.94(±1.19)D(范围为40.34至45.98 D),差异有统计学意义(p < 0.001)。在我们的患者中,PRK术后6个月,后表面Km与术前前表面Km通过以下回归公式相关:y = -4.9707x + 12.457(R² = 0.7656),其中x为术后后表面Km,y为术前前表面Km,与斋木计算的公式相似。

结论

在使用斋木公式计算接受PRK患者的术前Km时应谨慎。