Artunc Ulkumen B, Pala H G, Uyar Y, Koyuncu F M, Bulbul Baytur Y
a Division of Perinatology, Department of Obstetrics and Gynecology , Celal Bayar University School of Medicine , Manisa , Turkey.
J Obstet Gynaecol. 2015;35(5):447-50. doi: 10.3109/01443615.2014.968115.
We aimed to evaluate the volumetric and echogenic alterations in placentas between the intrauterine growth restriction (IUGR) and normal pregnancies using three-dimensional ultrasound and virtual organ computer-aided analysis (VOCAL) software. This case-control prospective study consisted of 48 singleton pregnancies complicated by IUGR and 60 healthy singleton pregnancies matched for maternal age, gestational age and parity. Placental volume (PV) and placental volumetric mean grey values (MGV) were evaluated. PV (cm(3)) was analysed using the VOCAL imaging analysis program, and 3D histogram was used to calculate the volumetric MGV (%). PV was 278.50 ± 63.68 and 370.98 ± 97.82 cm(3) in IUGR and control groups, respectively (p = 0.004). MGV of the placenta was 38.24 ± 8.41 and 38.24 ± 8.41 in IUGR and control groups, respectively (p = 0.30). receiver operator curve (ROC) curve analysis revealed that area under curve was 0.731 for PV. Correlation analysis revealed that PV was significantly associated with estimated fetal weight (r = 0.319, p = 0.003), biparietal diameter (r = 0.346, p = 0.002), head circumference (r = 0.269, p = 0.019), abdominal circumference (r = 0.344, p = 0.002) and femur length (r = 0.328, p = 0.004). PV was inversely related to the umbilical artery pulsatility index (r = - 0.244, p = 0.017). To the best of our knowledge, this is the first study evaluating volumetric MGV in IUGR placentas by comparing them with healthy pregnancies. Our study showed that PV diminishes significantly in IUGR pregnancies, whereas volumetric MGV does not alter significantly.
我们旨在使用三维超声和虚拟器官计算机辅助分析(VOCAL)软件评估宫内生长受限(IUGR)妊娠与正常妊娠胎盘的体积和回声变化。这项病例对照前瞻性研究包括48例单胎妊娠合并IUGR以及60例年龄、孕周和产次相匹配的健康单胎妊娠。评估胎盘体积(PV)和胎盘体积平均灰度值(MGV)。使用VOCAL成像分析程序分析PV(cm³),并使用三维直方图计算体积MGV(%)。IUGR组和对照组的PV分别为278.50±63.68和370.98±97.82 cm³(p = 0.004)。IUGR组和对照组胎盘的MGV分别为38.24±8.41和38.24±8.41(p = 0.30)。受试者工作特征(ROC)曲线分析显示,PV的曲线下面积为0.731。相关性分析显示,PV与估计胎儿体重显著相关(r = 0.319,p = 0.003)、双顶径(r = 0.346,p = 0.002)、头围(r = 0.269,p = 0.019)、腹围(r = 0.344,p = 0.002)和股骨长度(r = 0.328,p = 0.004)。PV与脐动脉搏动指数呈负相关(r = -0.244,p = 0.017)。据我们所知,这是第一项通过将IUGR胎盘与健康妊娠胎盘进行比较来评估体积MGV的研究。我们的研究表明,IUGR妊娠中PV显著减小,而体积MGV无显著改变。