We describe a technique for sutureless intrascleral fixation of a 3-piece intraocular lens (IOL) and custom silicone iris prosthesis complex to address the optical and functional issues of aphakia and aniridia, as well as to restore excellent cosmesis. The 3-piece IOL is anchored to the iris prosthesis using the belt-loop technique. We believe the intrascleral haptic fixation is overall a more robust fixation method in patients with aphakia and aniridia, who are often younger and require a long-lasting anterior segment reconstruction.
Dr. Ahmed is a consultant to Alcon Laboratories, Inc., and Abbott Medical Optics, Inc. No other author has a financial or proprietary interest in any material or method mentioned.
我们描述了一种用于三片式人工晶状体(IOL)和定制硅胶虹膜假体复合体的无缝合巩膜内固定技术,以解决无晶状体眼和无虹膜症的光学及功能问题,并恢复良好的美容效果。使用带袢技术将三片式人工晶状体固定于虹膜假体上。我们认为,对于通常较为年轻且需要长期前段重建的无晶状体眼和无虹膜症患者,巩膜内襻固定总体上是一种更可靠的固定方法。
艾哈迈德医生是爱尔康实验室公司和雅培医疗光学公司的顾问。其他作者在文中提及的任何材料或方法均无财务或专利权益。