Suppr超能文献

国产支架Cobal C的真实世界经验——一项回顾性研究。

Real world experience with an indigenously manufactured stent Cobal C--a retrospective study.

作者信息

Sastry B K S, Kumar Nirmal, Menon Rajeev, Kapadia Anuj, Sridevi C, Surya Prakash G, Krishna Reddy N, Srinivasa Rao M

机构信息

Consultant Cardiologist, CARE Hospitals, Hyderabad, Telangana, India.

CARE Hospitals, Hyderabad, Telangana, India.

出版信息

Indian Heart J. 2014 Sep-Oct;66(5):525-9. doi: 10.1016/j.ihj.2014.08.015. Epub 2014 Sep 18.

Abstract

BACKGROUND

Second generation bare metal stents made of cobalt chromium alloy are superior to first generation stain less steel stents. The thin struts are shown to reduce clinical and angiographic adverse outcomes.

OBJECTIVE

To study the long term clinical and angiographic outcomes in patients who underwent coronary angioplasty with an indigenously made cobalt chromium bare metal stents with thin strut Cobal+C™ (Relisys).

METHODS

A total of 268 consecutive patients who underwent coronary angioplasty with Cobal+C stents were studied retrospectively. Clinical follow up was done after a minimum period of nine months through telephonic interview and angiographic follow up was done in 80 patients chosen randomly. The end points analyzed included major adverse cardiac events (MACE) at nine months and the rate of binary restenosis at follow up angiogram done between 9 and 15 months post angioplasty.

RESULTS

Thirty four percent were diabetic and 33% had acute myocardial infarction. Females constituted 17%. Mean stent diameter was 2.88 ± 0.28 and mean stent length 18.8 ± 4.2. MACE at nine months was 4.5% with TLR 0.3%. The rate of binary restenosis was 21%. Patients with longer stent lengths and non-compliance with medications had significantly higher rates of binary restenosis.

CONCLUSIONS

The use of Relisys Cobal+C stents was associated with good long term clinical and angiographic outcomes as evidenced by low incidence of MACE and binary restenosis rates for a bare metal stent.

摘要

背景

由钴铬合金制成的第二代裸金属支架优于第一代不锈钢支架。研究表明,较薄的支架小梁可减少临床和血管造影的不良后果。

目的

研究使用国产的带有薄支架小梁的钴铬裸金属支架Cobal+C™(Relisys)进行冠状动脉血管成形术患者的长期临床和血管造影结果。

方法

对268例连续使用Cobal+C支架进行冠状动脉血管成形术的患者进行回顾性研究。通过电话随访至少9个月进行临床随访,并对随机选择的80例患者进行血管造影随访。分析的终点包括9个月时的主要不良心脏事件(MACE)以及血管成形术后9至15个月进行的随访血管造影时的二元再狭窄率。

结果

34%为糖尿病患者,33%有急性心肌梗死。女性占17%。平均支架直径为2.88±0.28,平均支架长度为18.8±4.2。9个月时的MACE为4.5%,靶病变血运重建(TLR)为0.3%。二元再狭窄率为21%。支架长度较长且不依从药物治疗的患者二元再狭窄率明显更高。

结论

使用Relisys Cobal+C支架具有良好的长期临床和血管造影结果,这一点从MACE发生率低以及裸金属支架的二元再狭窄率可以得到证明。

相似文献

本文引用的文献

1
The CID Chrono cobalt-chromium alloy carbofilm-coated coronary stent system.CID Chrono 钴铬合金碳覆膜冠状动脉支架系统。
Int J Cardiol. 2011 Jun 2;149(2):199-204. doi: 10.1016/j.ijcard.2010.01.009. Epub 2010 Feb 6.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验