Suppr超能文献

动脉瘤中的血流非依赖动力学:颈内动脉瘤完全血流停止后的瘤内压力测量

Flow-independent dynamics in aneurysms: intra-aneurysm pressure measurements following complete flow cessation in internal carotid artery aneurysms.

作者信息

Qureshi Adnan I, Qureshi Mushtaq H, Mohindroo Tanya, Khan Asif A, Dingmann Kayla, Sherr Gregory T, Suri M Fareed K

机构信息

Zeenat Qureshi Stroke Institute, and Department of Cerebrovascular Diseases, CentraCare Health, St. Cloud, Minnesota, USA.

出版信息

J Endovasc Ther. 2014 Dec;21(6):861-6. doi: 10.1583/14-4789R.1.

Abstract

PURPOSE

To determine if complete flow obliteration by covered stents reduces intra-aneurysm pressures in internal carotid artery (ICA) aneurysms.

METHODS

A single lumen microcatheter was placed into the aneurysm sac prior to covered stent deployment in 3 patients and connected to a pressure monitoring system. The intra-aneurysm pressure was continuously monitored, and readings were recorded prior to and immediately after stent deployment and at 5-minute intervals up to 20 minutes after stent placement. Complete occlusion of flow into the aneurysms was confirmed by carotid angiography.

RESULTS

There was no change in mean pressure within the aneurysm before and immediately after stent placement (80 mmHg) in any patient, nor was there a change in waveform of the intra-aneurysm pressure recording. The average of intra-aneurysm pressures among the 3 patients was higher (99 mmHg) at 10 and 15 minutes after stent placement. In 2 patients, the microcatheter was retracted into the parent arterial lumen; no difference in pressure was noted.

CONCLUSION

Our observations suggest no change in the pressures within the aneurysm after complete flow cessation (flow-independent). These findings may assist clinicians in better understanding aneurysm hemodynamics and rupture after covered stent deployment.

摘要

目的

确定覆膜支架完全闭塞血流是否能降低颈内动脉(ICA)动脉瘤内的压力。

方法

在3例患者中,于置入覆膜支架前将单腔微导管置入动脉瘤腔内,并连接至压力监测系统。持续监测动脉瘤内压力,在支架置入前、置入后即刻以及置入后直至20分钟每隔5分钟记录读数。通过颈动脉血管造影确认动脉瘤内血流完全闭塞。

结果

在任何患者中,支架置入前及置入后即刻动脉瘤内平均压力均无变化(80 mmHg),动脉瘤内压力记录的波形也无变化。3例患者在支架置入后10分钟和15分钟时动脉瘤内压力平均值较高(99 mmHg)。在2例患者中,将微导管撤回至母动脉腔内;未观察到压力差异。

结论

我们的观察结果表明,血流完全停止后(与血流无关)动脉瘤内压力无变化。这些发现可能有助于临床医生更好地理解覆膜支架置入后动脉瘤的血流动力学和破裂情况。