Suppr超能文献

The ability of massive osteochondral allografts from the medial tibial plateau to reproduce normal joint contact pressures after glenoid resurfacing: the effect of computed tomography matching.

作者信息

Millett Peter J, Euler Simon A, Dornan Grant J, Smith Sean D, Collins Tyler, Michalski Max P, Spiegl Ulrich J, Jansson Kyle S, Wijdicks Coen A

机构信息

Steadman Philippon Research Institute, Vail, CO, USA; The Steadman Clinic, Vail, CO, USA.

Steadman Philippon Research Institute, Vail, CO, USA; The Steadman Clinic, Vail, CO, USA; Department of Trauma Surgery and Sports Traumatology, Medical University Innsbruck, Innsbruck, Austria.

出版信息

J Shoulder Elbow Surg. 2015 May;24(5):e125-34. doi: 10.1016/j.jse.2014.09.033. Epub 2014 Nov 6.

Abstract

BACKGROUND

Current techniques for resurfacing of the glenoid in the treatment of arthritis are unpredictable. Computed tomography (CT) studies have demonstrated that the medial tibial plateau has close similarity to the glenoid. The purpose of this study was to assess contact pressures of transplanted massive tibial osteochondral allografts to resurface the glenoid without and with CT matching.

METHODS

Ten unmatched cadaveric tibiae were used to resurface 10 cadaveric glenoids with osteochondral allografts. Five cadaveric tibiae and glenoids were CT matched and studied. An internal control group of 4 matched pairs of glenoids, with the contralateral glenoid transplanted to the opposite glenoid, was also included as a best-case scenario to measure the effects of the surgical technique. All glenoids were tested before and after grafting at different abduction and rotation angles, with recording of peak contact pressures.

RESULTS

Peak contact pressures were not different from the intact state in the autografted group but were increased in both allografted groups. CT-matched tibial grafts had lower peak pressures than unmatched grafts. Peak pressures were on average 24.8% (range [18.3%, 29.6%]) greater than in the native glenoids for unmatched allografts, 21.8% ([17.0%, 25.5%]) greater for the matched allografts, and 4.9% ([3.8%, 5.5%]) greater for matched autografts.

CONCLUSION

Osteochondral grafting from the medial tibial plateau to the glenoid is feasible but results in increased peak contact pressures. The technique is reproducible as defined by the autografted group. Contact pressures between native and allografted glenoids were significantly different. The clinical significance remains unknown. Peak pressures experienced by the glenoid seem highly sensitive to deviations from the native glenoid shape.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验