Frellesen Claudia, Boettcher Marie, Wichmann Julian L, Drieske Martina, Kerl J Matthias, Lehnert Thomas, Nau Christoph, Geiger Emmanuel, Wutzler Sebastian, Ackermann Hanns, Vogl Thomas J, Bauer Ralf W
Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Frankfurt, Germany.
Department of Trauma, Reconstructive and Hand Surgery, Clinic of the Goethe University, Frankfurt, Germany.
Eur J Radiol. 2015 Jan;84(1):117-122. doi: 10.1016/j.ejrad.2014.10.013. Epub 2014 Nov 1.
To reveal the impact on workflow from introducing a dual-room sliding gantry CT to the trauma room for polytrauma and regularly scheduled in- outpatients with regard to efficiency and degree of capacity utilisation.
Time analysis was performed for 30 polytrauma patients each in 2 different trauma room settings, the new trauma room comprising a sliding gantry CT, the old one a stationary single-room CT. Complete trauma room and diagnostic workup times were manually measured and compared for both groups. In a third scenario, the number of CT scans performed with one single sliding gantry CT and the two-room concept was compared to the number of CT scans performed on two separate regular CT units in a 5 days clinical routine sample.
Patients demographics and type of CT examinations were comparable for all patient groups. The median time from patient arrival in the trauma room until beginning of CT scanning was 6 min shorter for the sliding gantry CT group (21 vs.15 min). Sliding gantry CT embedded in a two-room solution achieved 252 CT scans in 5 working days, compared to 250 CT scans on two separate regular CT units with the same man power.
Sliding gantry CT in the trauma room allows for significant time saving in the diagnostic workup of polytrauma patients and faster resumption of the regular in- outpatient's CT schedule is possible. With the same man power, the dual-room solution is able to generate the same throughput as two separate CT units.
揭示将双室滑动门架CT引入创伤室,对多发伤患者以及定期安排的门诊患者的工作流程在效率和容量利用率方面的影响。
在两种不同的创伤室设置下,对30例多发伤患者进行了时间分析,新的创伤室配备滑动门架CT,旧的配备固定式单室CT。手动测量并比较了两组患者在创伤室的完整检查时间和诊断检查时间。在第三种情况下,将一台单滑动门架CT和双室概念下进行的CT扫描数量,与在5天临床常规样本中两台单独的常规CT设备上进行的CT扫描数量进行了比较。
所有患者组的患者人口统计学特征和CT检查类型具有可比性。滑动门架CT组从患者到达创伤室到开始CT扫描的中位时间缩短了6分钟(21分钟对15分钟)。在双室解决方案中嵌入的滑动门架CT在5个工作日内完成了252次CT扫描,而在人力相同的情况下,两台单独的常规CT设备完成了250次CT扫描。
创伤室中的滑动门架CT可显著节省多发伤患者的诊断检查时间,并有可能更快恢复常规门诊患者的CT检查安排。在人力相同的情况下,双室解决方案能够产生与两台单独的CT设备相同的吞吐量。