OBJECTIVE

Obstructive sleep apnea syndrome (OSAS) may affect voice performance due to alterations that occur in the upper respiratory tract. The aim of the study was to assess the effect of OSAS and continuous positive airway pressure (CPAP) treatment on voice performance.

MATERIALS AND METHODS

Twenty-seven patients with moderate to severe OSAS (apnea-hypopnea index ≥15/h) who underwent polysomnographic examination and 28 age- and gender-matched normal control subjects were enrolled in the study. The patients and the control subjects completed Voice Handicap Index (VHI) questionnaires, and their acoustic voice analyses were performed. Fundamental frequency (F0), jitter %, and shimmer % parameters were statistically compared. Acoustic analyses were performed again 1 month after regular CPAP use in OSAS patients, and the parameters before and after the treatment were compared.

RESULTS

F0 was 160.82 Hz, jitter was 0.70%, shimmer was 1.05%, and VHI was 1.18 in the control group. In OSAS patients before CPAP treatment, F0 was 157.04 Hz, jitter was 0.82%, shimmer was 1.33%, and VHI was 13.11. These results showed that shimmer and VHI parameters were significantly worse in OSAS patients. After CPAP treatment, F0 was 169.19 Hz, jitter was 0.62%, shimmer was 0.93% and VHI was 5.00. The differences were statistically significant in all parameters.

CONCLUSION

The acoustic parameters of OSAS patients differed from those of the normal control subjects. The patients' voice performance improved after a regular use of CPAP treatment for 1 month.

摘要

目的

阻塞性睡眠呼吸暂停综合征(OSAS)可能因上呼吸道发生的改变而影响嗓音表现。本研究的目的是评估OSAS及持续气道正压通气(CPAP)治疗对嗓音表现的影响。

材料与方法

本研究纳入了27例接受多导睡眠图检查的中重度OSAS患者(呼吸暂停低通气指数≥15次/小时)以及28例年龄和性别匹配的正常对照者。患者和对照者完成嗓音障碍指数(VHI)问卷,并进行嗓音声学分析。对基频(F0)、抖动百分比和闪烁百分比参数进行统计学比较。OSAS患者规律使用CPAP 1个月后再次进行声学分析,并比较治疗前后的参数。

结果

对照组的F0为160.82Hz,抖动为0.70%,闪烁为1.05%,VHI为1.18。在CPAP治疗前的OSAS患者中,F0为157.04Hz,抖动为0.82%,闪烁为1.33%,VHI为13.11。这些结果表明,OSAS患者的闪烁和VHI参数明显更差。CPAP治疗后,F0为169.19Hz,抖动为0.62%,闪烁为0.93%,VHI为5.00。所有参数的差异均具有统计学意义。

结论

OSAS患者的声学参数与正常对照者不同。OSAS患者规律使用CPAP治疗1个月后嗓音表现有所改善。