Suppr超能文献

金属和塑料支架用于胰液积聚经壁引流的疗效:一项系统评价

Efficacy of metal and plastic stents for transmural drainage of pancreatic fluid collections: a systematic review.

作者信息

Bang Ji Young, Hawes Robert, Bartolucci Albert, Varadarajulu Shyam

机构信息

Division of Gastroenterology & Hepatology, Indiana University, Indianapolis, USA.

Center for Interventional Endoscopy, Florida Hospital, Orlando, USA.

出版信息

Dig Endosc. 2015 May;27(4):486-498. doi: 10.1111/den.12418. Epub 2015 Jan 16.

Abstract

BACKGROUND AND AIM

Metal stents are being used more frequently for transmural endoscopic drainage of pancreatic fluid collections (PFC) despite lack of data. The present systematic review was conducted to compare the rates of treatment success, adverse events and recurrence between patients undergoing metal versus plastic stent placement for endoscopic transmural drainage of PFC.

METHODS

MEDLINE and EMBASE were searched to identify all published manuscripts that evaluated metal stents for endoscopic transmural drainage of PFC. All published studies from the same period involving plastic stent placement for PFC drainage that included >50 patients were also identified. Main outcome measures were to compare the rates of treatment success, adverse events and recurrence between the metal and plastic stent cohorts.

RESULTS

Seventeen studies (881 patients) met inclusion criteria. There was no difference in overall treatment success between patients treated with plastic and metal stents (81% [95% CI, 77-84%] vs 82% [95% CI, 74-88%]) for both pseudocysts (85% [95% CI, 81-89%] vs 83% [95% CI, 74-89%]) and walled-off necrosis (70% [95% CI, 62-76%] vs 78% [95% CI, 50-93%]). Also, there was no difference in the rates of adverse events (16% [95% CI, 14-39%] vs 23% [95% CI, 16-33%]) or recurrence (10% [95% CI, 8-13%] vs 9% [95% CI, 4-19%]) between plastic and metal stents.

CONCLUSIONS

Current evidence does not support routine placement of metal stents for transmural drainage of PFC. Randomized trials are needed to justify the use of metal stents for PFC drainage.

摘要

背景与目的

尽管缺乏相关数据,但金属支架在经壁内镜引流胰腺液体积聚(PFC)中的应用越来越频繁。本系统评价旨在比较接受金属支架与塑料支架置入术进行PFC内镜经壁引流的患者在治疗成功率、不良事件及复发率方面的差异。

方法

检索MEDLINE和EMBASE,以确定所有评估金属支架用于PFC内镜经壁引流的已发表手稿。同时确定同一时期所有发表的涉及置入塑料支架引流PFC且纳入患者超过50例的研究。主要观察指标是比较金属支架组与塑料支架组在治疗成功率、不良事件及复发率方面的差异。

结果

17项研究(881例患者)符合纳入标准。对于假性囊肿(85%[95%CI,81 - 89%]对83%[95%CI,74 - 89%])和包裹性坏死(70%[95%CI,62 - 76%]对78%[95%CI,50 - 93%]),接受塑料支架和金属支架治疗的患者在总体治疗成功率上无差异(分别为81%[95%CI,77 - 84%]和82%[CI,74 - 88%])。此外,塑料支架和金属支架在不良事件发生率(16%[95%CI,14 - 39%]对23%[95%CI,16 - 33%])或复发率(10%[95%CI,8 - 13%]对9%[95%CI,4 - 19%])方面也无差异。

结论

目前的证据不支持常规使用金属支架进行PFC经壁引流。需要进行随机试验来证明使用金属支架进行PFC引流的合理性。