Material model calibration from planar tension tests on porcine linea alba.

作者信息

Acosta Santamaría Víctor, Siret Olivier, Badel Pierre, Guerin Gaëtan, Novacek Vít, Turquier Frédéric, Avril Stéphane

机构信息

Ecole Nationale Supérieure des Mines de Saint Etienne, CIS-EMSE, CNRS:UMR5307, LGF, 158 Cours Fauriel, 42023 Saint-Etienne Cedex 2, France.

Ecole Nationale Supérieure des Mines de Saint Etienne, CIS-EMSE, CNRS:UMR5307, LGF, 158 Cours Fauriel, 42023 Saint-Etienne Cedex 2, France.

出版信息

J Mech Behav Biomed Mater. 2015 Mar;43:26-34. doi: 10.1016/j.jmbbm.2014.12.003. Epub 2014 Dec 13.


DOI:10.1016/j.jmbbm.2014.12.003
PMID:25553553
Abstract

The purpose of this study was to determine biomechanical properties of linea alba subjected to transverse planar tension and to compare its behavior at different locations of the abdominal wall. Samples of linea alba from five different porcine abdominal walls were tested in planar tension. During these tests, strain maps were measured for the first time ever using the stereo-digital image correlation (S-DIC) technique. The strain maps were used to derive the properties of different hyperelastic material models. It was shown that the Ogden model and the Holzapfel-Gasser-Ogden model are appropriate to reproduce the response in planar tension. The linea alba located above the umbilicus was significantly more compliant than below the umbilicus. This difference which is reported for the first time here is consistent with the tissue microstructure and it is discussed within the perspective of clinically-relevant numerical simulations.

摘要

相似文献

[1]
Material model calibration from planar tension tests on porcine linea alba.

J Mech Behav Biomed Mater. 2015-3

[2]
Uniaxial and biaxial mechanical properties of porcine linea alba.

J Mech Behav Biomed Mater. 2014-10-7

[3]
Uniaxial and biaxial tensile stress-stretch response of human linea alba.

J Mech Behav Biomed Mater. 2016-10

[4]
Anisotropy of human linea alba: a biomechanical study.

J Surg Res. 2005-3

[5]
An in vitro biomechanical comparison of the breaking strength and stiffness of polydioxanone (sizes 2, 7) and polyglactin 910 (sizes 3, 6) in the equine linea alba.

Vet Surg. 2005

[6]
Determination of passive viscoelastic response of the abdominal muscle and related constitutive modeling: stress-relaxation behavior.

J Mech Behav Biomed Mater. 2014-4-18

[7]
Mechanical characterization of brain tissue in tension at dynamic strain rates.

J Mech Behav Biomed Mater. 2012-9-10

[8]
Mechanical characterization of human brain tissue.

Acta Biomater. 2017-1-15

[9]
The normal width of the linea alba in nulliparous women.

Clin Anat. 2009-9

[10]
Contribution of collagen and elastin fibers to the mechanical behavior of an abdominal connective tissue.

J Mech Behav Biomed Mater. 2016-8