Sun Min, Feng Juanjuan, Bu Yanan, Wang Xiaojiao, Duan Huimin, Luo Chuannan
Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong (University of Jinan), School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China.
Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong (University of Jinan), School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China.
Talanta. 2015 Mar;134:200-205. doi: 10.1016/j.talanta.2014.11.005. Epub 2014 Nov 8.
A graphene coating bonded onto stainless steel wire was fabricated and investigated as a solid-phase microextraction fiber. The coating was characterized by scanning electron microscopy and energy-dispersive X-ray spectrometer. The coating with rough and crinkled structure was about 1 μm. These characteristics were helpful for promoting extraction. Using five n-alkanes (n-undecane, n-dodecane, n-tridecane, n-tetradecane and n-hexadecane) as analytes, the fiber was evaluated in direct-immersion mode by coupling with gas chromatography (GC). Through optimizing extraction and desorption conditions, a sensitive SPME-GC analytical method was established. SPME-GC method provided wide linearity range (0.2-150 μg L(-1)) and low limits of determination (0.05-0.5 μg L(-1)). It was applied to analyze rain water and a soil sample, and analytes were quantified in the range of 0.85-1.96 μg L(-1) and 0.09-3.34 μg g(-1), respectively. The recoveries of samples spiked at 10 μg L(-1) were in the range of 90.1-120% and 80.6-94.2%, respectively. The fiber also exhibited high thermal and chemical stability, due to the covalent bonds between graphene coating and wire, and the natural resistance of graphene for thermal, acid and basic conditions.