Thirty acrylic-resin blocks with a curvature of 60° and size#10 (2% taper) were assigned into two groups (n= 15). In group 1, the glide path was performed using stainless steel k-files size#10 and 15 at working length In group 2, canals were prepared with Reciproc file system at working length. By using digital imaging software (AutoCAD 2008), the pre-instrumentation and post-instrumentation digital images were superimposed over, taking the landmarks as reference points. Then the radius of the internal and external curve of the specimens was calculated at three α, β and γ points (1mm to apex as α, 3mm to apex as β, and 5mm to apex as γ). The data were statically analyzed using the independent T-test and Mann-Whitney U test by SPSS version 16.
Glide path was found significant for only external curve in the apical third of the canal; that is, 5mm to apex (P=0.005). But in the other third, canal modification was not significant (P> 0.008).
Canal transportation in the apical third of the canal seems to be significantly reduced when glide path is performed using reciprocating files.
理想的根管预备目的是预防诸如根管偏移等医源性异常情况。本研究的目的是评估使用和不使用引导通路时Reciproc锉的根管偏移情况。
将30个弯曲度为60°、尺寸为#10(锥度2%)的丙烯酸树脂块分为两组(n = 15)。在第1组中,使用尺寸为#10和15的不锈钢K锉在工作长度处制备引导通路。在第2组中,使用Reciproc锉系统在工作长度处预备根管。通过使用数字成像软件(AutoCAD 2008),将预备前和预备后的数字图像进行叠加,以标志点作为参考点。然后在三个α、β和γ点(距根尖1mm为α,距根尖3mm为β,距根尖5mm为γ)计算标本内外曲线的半径。使用SPSS 16版的独立T检验和曼-惠特尼U检验对数据进行统计学分析。
发现引导通路仅对根管根尖三分之一处的外曲线有显著影响;即距根尖5mm处(P = 0.005)。但在其他三分之一处,根管形态改变不显著(P > 0.008)。
当使用往复式锉进行引导通路制备时,根管根尖三分之一处的根管偏移似乎会显著减少。