使用临床简单设备评估人体口腔内热敏感性:对口面疼痛状况的影响。

Assessment of human intraoral thermal sensitivity with simple devices in the clinic: implications for orofacial pain conditions.

出版信息

J Oral Facial Pain Headache. 2015 Winter;29(1):83-90. doi: 10.11607/ofph.1221.

Abstract

AIMS

To use simple thermal devices with different diameters and temperatures to investigate reliability and magnitude of human intraoral thermal sensitivity.

METHODS

Sixteen healthy volunteers participated. Six thermal devices with tapered circular ends (stimulus diameter 3, 5, and 10 mm) were used. Three different temperatures (room temperature, heat, and cold) were applied with each of the three diameters, ie, nine combinations. Participants were stimulated in randomized order at nine different sites: tongue, lip, maxillary attached gingiva adjacent to the left and right central incisors (without touching the lip) and to the left and right premolars (with or without touching the lip), and the left and right cheeks extraorally. Participants rated the perceived stimulus intensity on 0-50- 100 numeric rating scales (NRS). The number of paradoxical thermal sensations was also recorded. Ten volunteers were examined twice on the same day and recalled for a second session for assessment with the 5-mm-diameter device of within- and between-session reliability (interclass correlation coefficients [ICC]). The results were analyzed using a three-way analysis of variance.

RESULTS

Reliability of NRS scores ranged from poor (ICC = 0.09, with cold stimulation at the premolar region) to excellent (ICC > 0.92, with cold stimulation at the cheek or tongue). NRS values varied with stimulus diameter (P < .050), temperature (P < .001), and sites (P < .001), with significant size x site and temperature x site interactions (P < .001). The tongue was the most sensitive site (P < .001) and the gingiva was the least sensitive site (P < .050). The 10-mm-diameter device produced higher NRS scores than the 3-mm-diameter device.

CONCLUSION

The reliability of intraoral thermal sensitivity recorded with the 5-mm-diameter device varied greatly between different sites. Nonetheless, with this caveat in mind, the study did document that semiquantitative assessment of intraoral thermal sensitivity is feasible and applicable for clinical studies in different intraoral pain conditions.

摘要

目的

使用不同直径和温度的简单热设备来研究人类口腔内热敏感性的可靠性和幅度。

方法

16 名健康志愿者参与。使用带有锥形圆形末端的六个热设备(刺激直径 3、5 和 10 毫米)。用三个不同的温度(室温、热和冷)应用于三个直径中的每一个,即九个组合。参与者以随机顺序在九个不同的部位进行刺激:舌头、嘴唇、上颌附着牙龈,紧邻左右中切牙(不接触嘴唇)和左右前磨牙(接触或不接触嘴唇),以及左右脸颊外部。参与者在 0-50-100 数字评分量表(NRS)上对感知到的刺激强度进行评分。还记录了反常热感觉的数量。十名志愿者在同一天接受两次检查,并召回第二次使用 5 毫米直径的设备进行评估,以评估日内和日内的可靠性(组内相关系数 [ICC])。结果使用三因素方差分析进行分析。

结果

NRS 评分的可靠性从差(ICC=0.09,冷刺激在前磨牙区)到极好(ICC>0.92,冷刺激在颊部或舌部)不等。NRS 值随刺激直径(P<.050)、温度(P<.001)和部位(P<.001)而变化,部位 x 大小和温度 x 部位的交互作用有统计学意义(P<.001)。舌头是最敏感的部位(P<.001),牙龈是最不敏感的部位(P<.050)。10 毫米直径的设备产生的 NRS 评分高于 3 毫米直径的设备。

结论

用 5 毫米直径的设备记录的口腔内热敏感性的可靠性在不同部位之间差异很大。尽管如此,考虑到这一警告,该研究确实记录了口腔内热敏感性的半定量评估是可行的,适用于不同口腔内疼痛情况下的临床研究。