Marques Eduardo F, Ferreira Tiago B
From the Cruz Vermelha Hospital (Marques) and Egas Moniz Hospital (Ferreira), Lisbon, Portugal.
From the Cruz Vermelha Hospital (Marques) and Egas Moniz Hospital (Ferreira), Lisbon, Portugal.
J Cataract Refract Surg. 2015 Feb;41(2):354-63. doi: 10.1016/j.jcrs.2014.05.048.
To compare the visual outcomes after cataract surgery with bilateral implantation of 1 of 2 diffractive trifocal intraocular lenses (IOLs).
Two clinical centers, Lisbon, Portugal.
Prospective comparative case series.
Phacoemulsification with bilateral implantation of a Finevision Micro F IOL (Group 1) or an AT Lisa tri 839 MP IOL (Group 2) was performed. Over a 3-month follow-up, the main outcome measures were uncorrected distance visual acuity (UDVA), corrected monocular and binocular distance visual acuity, uncorrected intermediate visual acuity at 80 cm, distance-corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity at 40 cm, distance-corrected near visual acuity (DCNVA), spherical equivalent (SE) refraction, defocus curves, contrast sensitivity, presence of dysphotopsia, and use of spectacles.
Each group comprised 30 eyes (15 patients). The mean values at 3 months were UDVA, 0.03 logMAR ± 0.08 (SD) (Group 1) and 0.08 ± 0.12 (Group 2) (P = .765); DCIVA, 0.04 ± 0.07 logMAR and 0.18 ± 0.18 logMAR, respectively (P = .048); DCNVA, 0.03 ± 0.06 logMAR and 0.11 ± 0.08 logMAR, respectively (P = .032); SE, -0.25 ± 0.30 diopter (D) and -0.02 ± 0.39 D, respectively (P = .087). There was no significant difference in contrast sensitivity or dysphotopic phenomena between groups.
Both trifocal IOL models provided excellent distance, intermediate, and near visual outcomes. Monocular DCIVA and DCNVA appeared slightly better in Group 1. Predictability of the refractive results and optical performance were excellent, and all patients achieved spectacle independence.
Neither author has a financial or proprietary interest in any material or method mentioned.
比较白内障手术后植入两种衍射三焦点人工晶状体(IOL)中一种的双眼视觉效果。
葡萄牙里斯本的两个临床中心。
前瞻性比较病例系列。
进行白内障超声乳化术并双眼植入Finevision Micro F IOL(第1组)或AT Lisa tri 839 MP IOL(第2组)。在3个月的随访中,主要观察指标为未矫正远视力(UDVA)、矫正的单眼和双眼远视力、80 cm处的未矫正中间视力、距离矫正中间视力(DCIVA)、40 cm处的未矫正近视力、距离矫正近视力(DCNVA)、等效球镜(SE)屈光度、散焦曲线、对比敏感度、畏光现象的存在情况以及眼镜的使用情况。
每组包括30只眼(15例患者)。3个月时的平均值为:UDVA,第1组为0.03 logMAR±0.08(标准差),第2组为0.08±0.12(P = 0.765);DCIVA,分别为0.04±0.07 logMAR和0.18±0.18 logMAR(P = 0.048);DCNVA,分别为0.03±0.06 logMAR和0.11±0.08 logMAR(P = 0.032);SE,分别为-0.25±0.30屈光度(D)和-0.02±0.39 D(P = 0.087)。两组之间对比敏感度或畏光现象无显著差异。
两种三焦点IOL模型均提供了出色的远、中、近视力效果。第1组的单眼DCIVA和DCNVA似乎略好。屈光结果的可预测性和光学性能极佳,所有患者均无需佩戴眼镜。
两位作者均对文中提及的任何材料或方法无财务或专有权益。