Suppr超能文献

Fractional cholesterol absorption measurements in humans: determinants of the blood-based dual stable isotope tracer technique.

作者信息

Stellaard Frans, Lütjohann Dieter

机构信息

Center for Liver, Digestive and Metabolic Diseases, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.

Institute for Clinical Chemistry and Clinical Pharmacology, University Clinics, Bonn, Germany.

出版信息

J Clin Lipidol. 2015 Jan-Feb;9(1):14-25. doi: 10.1016/j.jacl.2014.11.002. Epub 2014 Nov 13.

Abstract

BACKGROUND

The flux of absorbed cholesterol is a controlling element in the regulation of cholesterol biosynthesis and catabolism. A review of 5 published methods to measure cholesterol absorption is presented, including 2 dual stable isotope approaches. The continuous dual isotope feeding procedure is accurate, but only suitable for small-scale studies. The blood-based dual stable isotope technique is the least invasive and complex procedure, but leads to large variations in individual (<10%->90%) and mean population values (24%-70%) for healthy subjects. The results may be partly determined by the experimental and analytical procedures.

SOURCES OF MATERIAL

Fifteen blood-based dual stable isotope studies published between 1993 and 2013 have been analyzed. The results were related to the methodologies applied and evidence was sought for accordance to the test principles.

FINDINGS

Seven different isotopic tracers, 3 cholesterol subcompartments in blood, and 6 mass spectrometry techniques were applied. The oral and intravenous test formulations were presented in only 1 study. Time points for blood sampling and methodologies for blood sample preparation and analysis were highly variable. No definite proofs were supplied for the fates of the oral and intravenous cholesterol tracers. Isotope enrichment measurements in free and total cholesterol in plasma and erythrocytes were never compared. Fractional cholesterol absorption rate values depend strongly on the mass spectrometry methodology. Dual-inlet isotope ratio mass spectrometry appears to be the method of choice.

CONCLUSIONS

Dual stable isotope approaches require validation and standardization of administration and analysis procedures. A control group must always be included to correct for methodological differences.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验