Suppr超能文献

[人牙龈成纤维细胞在微槽表面接触引导活性的比较研究]

[Comparative study on contact guidance activity of human gingival fibroblasts on microgroove surfaces].

作者信息

Lai Yingzhen, Chen Jiang

机构信息

Department of Oral Implantology, Affiliated Stomotological Hospital, Fujian Medical University, Fuzhou 350002, China.

Department of Oral Implantology, Affiliated Stomotological Hospital, Fujian Medical University, Fuzhou 350002, China. Email:

出版信息

Zhonghua Kou Qiang Yi Xue Za Zhi. 2015 Jan;50(1):33-7.

Abstract

OBJECTIVE

To compared the difference in contact guidance activity among microgroove surfaces with different sizes of human gingival fibroblast (HGF), with the hope of providing basis for size selection of microgroove for transmucosal part of dental implant.

METHODS

Basing on the size of HGF, microgroove titanium surfaces were fabricated by photolithography with parallel grooves: 15, 30 or 60 µm in width and 5 or 10 µm in depth. The groups that used different microgroove surfaces were denoted as T15/5, T15/10, T30/5, T30/10, T60/5, and T60/10. Group T0 (the control meanwhile was a sputter of titanium on a simple planar silicon substrate). The morphology that HGF arranged along the groove was analyzed by immunofluorescence staining. Difference in contact guidance activity was quantitatively compared basing on the consistency of nucleus arrangement and deformation ratio.

RESULTS

Microgroove groups had significantly higher consistency of nucleus arrangement and deformation ratio compared to the control group, with T60/10 had the highest consistency of 0.937±0.024, and T15/5 had the lowest consistency of 0.660±0.016 and T60/10 had the highest deformation ratio of 3.555±0.205, and T15/5 had the lowest deformation ratio of 1.819±0.011.

CONCLUSIONS

Microgroove surfaces of all the different sizes show contact guidance activity on HGF, and the contact guidance activity increases with the increase of width and depth.

摘要

目的

比较不同尺寸微槽表面对人牙龈成纤维细胞(HGF)接触导向活性的差异,以期为牙种植体穿黏膜部分微槽尺寸的选择提供依据。

方法

根据HGF的大小,通过光刻技术制备具有平行凹槽的微槽钛表面:宽度为15、30或60μm,深度为5或10μm。使用不同微槽表面的组分别标记为T15/5、T15/10、T30/5、T30/10、T60/5和T60/10。T0组(对照组)为在简单平面硅基板上溅射钛。通过免疫荧光染色分析HGF沿凹槽排列的形态。根据细胞核排列的一致性和变形率定量比较接触导向活性的差异。

结果

与对照组相比,微槽组的细胞核排列一致性和变形率显著更高,其中T60/10的一致性最高,为0.937±0.024,T15/5的一致性最低,为0.660±0.016;T60/10的变形率最高,为3.555±0.205,T15/5的变形率最低,为1.819±0.011。

结论

所有不同尺寸的微槽表面均对HGF显示出接触导向活性,且接触导向活性随宽度和深度的增加而增强。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验