Suppr超能文献

义齿牙厚度对薄型丙烯酸树脂基托断裂模式的影响:一项实验与有限元分析

Influence of denture tooth thickness on fracture mode of thin acrylic resin bases: An experimental and finite element analysis.

作者信息

Sekinishi Takashi, Inukai Shusuke, Murakami Natsuko, Wakabayashi Noriyuki

机构信息

Clinical Resident, Removable Partial Prosthodontics, Division of Oral Health Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.

Assistant Professor, Removable Partial Prosthodontics, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.

出版信息

J Prosthet Dent. 2015 Jul;114(1):122-9. doi: 10.1016/j.prosdent.2014.11.011. Epub 2015 Mar 17.

Abstract

STATEMENT OF PROBLEM

The optimum selection of denture teeth for patients with a reduced interarch distance has not been established.

PURPOSE

The purpose of this in vitro study was to investigate the influence of denture tooth material and thickness on the fracture resistance of thin acrylic resin denture bases.

MATERIAL AND METHODS

Acrylic resin (AC), composite resin (CO), or ceramic (CE) molar denture teeth were embedded in denture base blocks (2.0 mm thick). The distance from the central fossa to the tooth base was 0.5, 1.0, 2.0, or 2.5 mm for AC and CO, and 1.0 mm for CE (n=7), with a total thickness of 2.5 mm for all specimens. Each specimen was placed on a 3-point flexural setup with a shorter (8 mm) or longer (12 mm) support span than the tooth width and vertically loaded. A finite element analysis was performed to assess the stress distributions. The effects of tooth thickness and support span were statistically tested with ANOVA, followed by the Tukey honestly significant difference post hoc test (α= .05).

RESULTS

With the shorter support, the mean fracture load was higher in CO than AC, regardless of the tooth thickness. Under the longer support, the mean fracture load with the CO decreased significantly as the tooth thickness increased, with increased maximum stress. Some CO tooth specimens of 2.0 mm or 2.5 mm thickness failed at the tooth-denture base interface at significantly lower loads than those exhibited by tooth fractures. CE showed minor cracks before bulk fracture.

CONCLUSIONS

Higher fracture resistance was indicated with CO; however, the resistance decreased as the thickness of the CO tooth increased.

摘要

问题陈述

对于牙弓间距减小的患者,义齿牙齿的最佳选择尚未确定。

目的

本体外研究的目的是调查义齿牙齿材料和厚度对薄型丙烯酸树脂义齿基托抗折性的影响。

材料与方法

将丙烯酸树脂(AC)、复合树脂(CO)或陶瓷(CE)磨牙义齿牙嵌入厚度为2.0mm的义齿基托块中。对于AC和CO,从中央窝到牙基底部的距离为0.5、1.0、2.0或2.5mm,对于CE为1.0mm(n = 7),所有标本的总厚度为2.5mm。每个标本放置在一个三点弯曲装置上,支撑跨度比牙齿宽度短(8mm)或长(12mm),并垂直加载。进行有限元分析以评估应力分布。使用方差分析对牙齿厚度和支撑跨度的影响进行统计学检验,随后进行Tukey真实显著性差异事后检验(α = 0.05)。

结果

在较短支撑跨度下,无论牙齿厚度如何,CO的平均抗折载荷均高于AC。在较长支撑跨度下,随着牙齿厚度增加,CO的平均抗折载荷显著降低,最大应力增加。一些厚度为2.0mm或2.5mm的CO牙齿标本在牙齿与义齿基托界面处的破坏载荷明显低于牙齿折断时的载荷。CE在整体断裂前出现轻微裂纹。

结论

CO显示出较高的抗折性;然而,随着CO牙齿厚度的增加,其抗性降低。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验