Sánchez-Vicente J L, Rueda-Rueda T, González-García M L, López-Herrero F, Sánchez-Vicente P, Castilla-Lázpita A
Servicio de Oftalmología, Hospital Universitario Virgen del Rocío, Sevilla, España.
Servicio de Oftalmología, Hospital Universitario Virgen del Rocío, Sevilla, España.
Arch Soc Esp Oftalmol. 2015 Oct;90(10):494-6. doi: 10.1016/j.oftal.2015.02.010. Epub 2015 Mar 25.
We present the case of an 81-year-old man with retinal detachment caused by intrusion of an Arruga suture. The encircling buckle was located in the sub-retinal space and caused retinal breaks with retinal detachment
A pars plana vitrectomy was performed along with intraocular cutting of the Arruga suture with retinal re-attachment.
我们报告一例81岁男性因阿鲁加缝线侵入导致视网膜脱离的病例。环扎带位于视网膜下间隙,导致视网膜裂孔并伴有视网膜脱离。
进行了玻璃体切除术,并在眼内切断阿鲁加缝线,视网膜得以复位。