Suppr超能文献

经导管主动脉瓣置换术(TAVR)后发生的医源性二尖瓣狭窄。

Iatrogenic mitral stenosis following transcatheter aortic valve replacement (TAVR).

作者信息

Harries Iwan, Chandrasekaran Badrinathan, Barnes Edward, Ramcharitar Steve

机构信息

Wiltshire Cardiac Centre, Great Western Hospital, Marlborough Road, Swindon, Wiltshire SN3 6BB, UK.

Wiltshire Cardiac Centre, Great Western Hospital, Marlborough Road, Swindon, Wiltshire SN3 6BB, UK.

出版信息

Indian Heart J. 2015 Jan-Feb;67(1):60-1. doi: 10.1016/j.ihj.2015.02.005. Epub 2015 Mar 4.

Abstract

A 57 year old female underwent transcatheter aortic valve replacement (TAVR) for severe aortic stenosis. Mild iatrogenic mitral stenosis was noted intraoperatively. Attempts to reposition the device were hampered by aortic angulation. One year later, severe mitral stenosis was confirmed on transoesophageal echocardiography. It is important to recognise that iatorgenic mitral stenosis due to TAVR may progress over time. Care should be taken to minimise the risk of this rare complication.

摘要

一名57岁女性因严重主动脉瓣狭窄接受了经导管主动脉瓣置换术(TAVR)。术中发现轻度医源性二尖瓣狭窄。主动脉成角阻碍了器械重新定位的尝试。一年后,经食管超声心动图证实为严重二尖瓣狭窄。必须认识到,TAVR引起的医源性二尖瓣狭窄可能会随时间进展。应注意将这种罕见并发症的风险降至最低。

相似文献

1
Iatrogenic mitral stenosis following transcatheter aortic valve replacement (TAVR).
Indian Heart J. 2015 Jan-Feb;67(1):60-1. doi: 10.1016/j.ihj.2015.02.005. Epub 2015 Mar 4.
3
Transcatheter Aortic and Mitral Valve Implantation (TAMVI) in Native Rheumatic Valves.
J Card Surg. 2015 Nov;30(11):813-6. doi: 10.1111/jocs.12612. Epub 2015 Sep 8.
4
The risk and extent of neurologic events are equivalent for high-risk patients treated with transcatheter or surgical aortic valve replacement.
J Thorac Cardiovasc Surg. 2016 Jul;152(1):85-96. doi: 10.1016/j.jtcvs.2016.02.073. Epub 2016 Mar 12.
5
A three-dimensional echocardiographic study on aortic-mitral coupling in transcatheter aortic valve replacement.
Eur Heart J Cardiovasc Imaging. 2013 Oct;14(10):950-6. doi: 10.1093/ehjci/jet058. Epub 2013 May 29.
7
Impact of moderate to severe mitral stenosis in patients undergoing transcatheter aortic valve replacement.
Int J Cardiol. 2019 Jul 1;286:36-42. doi: 10.1016/j.ijcard.2019.03.053. Epub 2019 Mar 28.
9
Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis and Mitral Regurgitation.
Ann Thorac Surg. 2017 Dec;104(6):1977-1985. doi: 10.1016/j.athoracsur.2017.05.065. Epub 2017 Sep 29.
10
Mitral Valve Stenosis after Transcatheter Aortic Valve Replacement: Case Report and Review of the Literature.
Cardiovasc Revasc Med. 2019 Dec;20(12):1196-1202. doi: 10.1016/j.carrev.2019.02.023. Epub 2019 Mar 1.

引用本文的文献

1
Mitral complex geometric changes aggravate mitral stenosis after transcatheter aortic valve replacement.
Int J Cardiovasc Imaging. 2024 Aug;40(8):1767-1777. doi: 10.1007/s10554-024-03167-y. Epub 2024 Jul 6.
3
Previous TAVR in patients undergoing percutaneous edge-to-edge mitral valve repair (PMVR) affects improvement of MR.
PLoS One. 2018 Oct 19;13(10):e0205930. doi: 10.1371/journal.pone.0205930. eCollection 2018.

本文引用的文献

1
Transcatheter Aortic Valve Implantation (core valve) prosthesis complicated by mitral stenosis.
J Saudi Heart Assoc. 2012 Apr;24(2):149-50. doi: 10.1016/j.jsha.2012.02.007. Epub 2012 Mar 7.
2
Acute mitral stenosis after transcatheter aortic valve implantation.
J Am Coll Cardiol. 2012 Nov 13;60(20):e35. doi: 10.1016/j.jacc.2012.05.061.