Okuno Y, Hongo M, Ujiie H, Satake K, Toyota T
Department of 3rd Internal Medicine, Tohoku University, School of Medicine.
Nihon Heikatsukin Gakkai Zasshi. 1989 Apr;25(2):55-60. doi: 10.1540/jsmr1965.25.55.
In 1922, Alvarez made some electrical recordings from cutaneous electrodes, but the method has not been widely adopted. It has been caused by the technical difficulties in recording, and in extracting consistent information from the recording. Therefore in an effort to improve the ability to routinely obtain a recording of the gastric electrical activity, using cutaneous electrodes (electrogastrography, EGG), we have investigated different electrodes placement and bipolar recording techniques. We studied 10 healthy asymptomatic volunteers. Frequency and power product have been used to help interpret the potential change. We found significant frequency component at approximately 3 cycle/min. Recordings from the upper part of epigastrium were better than those from the lower part of epigastrium. This suggests that these recordings are taken from electrical activity of the stomach. We found the good placement of cutaneous electrodes and good recording techniques.
1922年,阿尔瓦雷斯用皮肤电极进行了一些电记录,但该方法尚未被广泛采用。这是由于记录以及从记录中提取一致信息存在技术困难。因此,为了提高使用皮肤电极(胃电图,EGG)常规获取胃电活动记录的能力,我们研究了不同的电极放置和双极记录技术。我们研究了10名健康无症状志愿者。频率和功率乘积已被用于帮助解释电位变化。我们在大约每分钟3个周期处发现了显著的频率成分。上腹部的记录比下腹部的记录更好。这表明这些记录取自胃的电活动。我们找到了皮肤电极的良好放置位置和良好的记录技术。