Evangelista Maristella S, Kim Eugene K, Evans Gregory R D, Wirth Garrett A
the Aesthetic and Plastic Surgery Institute, University of California Irvine, Orange, CA and Long Beach Memorial Medical Center, Long Beach, CA; email:
the Aesthetic and Plastic Surgery Institute, University of California Irvine, Orange, CA and Long Beach Memorial Medical Center, Long Beach, CA.
Wounds. 2013 Apr;25(4):89-93.
Optimal pressure settings have been suggested in the use of negative pressure wound therapy (NPWT) in wound dressings. When used as a bolster for skin grafting, an NPWT setting of 125 mm Hg was initially suggested, but not validated through studies. The objective of this study is to report findings on the effect of varied pressure settings on the incorporation of split thickness skin grafts when using an NPWT bolster.
From 2007 to 2010, 48 inpatients underwent split thickness skin grafting using a negative pressure system as a bolster under the care of 2 surgeons at 2 academic institutions. Twenty-two patients were evaluated retrospectively who were treated using NPWT bolsters at 75 mm Hg and 125 mm Hg based on the surgeon's discretion. Twenty-six patients were evaluated prospectively and were randomized to 50 mm Hg, 75 mm Hg, 100 mm Hg, and 125 mm Hg pressure settings. Graft incorporation was assessed at time of bolster removal, 2 weeks, and 4 weeks, per standard protocol.
At each assessment point, incorporation of each skin graft was > 95% in all study subjects, at all pressure settings.
Whereas initially postulated to be 125 mm Hg, ideal pressure settings for NPWT, when used as a bolster for split thickness skin grafts, may be lower. This study suggests that pressures as low as 50 mm Hg can be tolerated without compromise of skin graft incorporation. Study findings were presented at the Plastic Surgery Research Council Meeting in San Francisco, CA in April of 2010. .
负压伤口治疗(NPWT)用于伤口敷料时,已有人提出最佳压力设置。当用作皮肤移植的支撑物时,最初建议NPWT设置为125毫米汞柱,但未通过研究验证。本研究的目的是报告在使用NPWT支撑物时,不同压力设置对中厚皮片移植成活情况影响的研究结果。
2007年至2010年,两所学术机构的两名外科医生对48例住院患者进行了中厚皮片移植,并使用负压系统作为支撑物。回顾性评估了22例患者,这些患者根据外科医生的判断分别接受了75毫米汞柱和125毫米汞柱的NPWT支撑治疗。前瞻性评估了26例患者,并将其随机分为50毫米汞柱、75毫米汞柱、100毫米汞柱和125毫米汞柱压力设置组。按照标准方案,在移除支撑物时、2周和4周时评估皮片成活情况。
在所有评估点,所有研究对象在所有压力设置下,每个皮肤移植片的成活率均>95%。
虽然最初假定为125毫米汞柱,但NPWT用作中厚皮片移植的支撑物时,理想的压力设置可能更低。本研究表明,低至50毫米汞柱的压力也能耐受,且不影响皮肤移植片的成活。研究结果于2010年4月在加利福尼亚州旧金山举行的整形外科学术研究委员会会议上公布。