Ebili Henry O, Ilyas Mohammad
Morbid Anatomy and Histopathology Department, Olabisi Onabanjo University, Ago-Iwoye, Nigeria ; University College Hospital, Ibadan, Nigeria.
Division of Pathology, University of Nottingham, Queen's Medical Centre Campus, Nottingham, UK.
Ecancermedicalscience. 2015 Apr 15;9:522. doi: 10.3332/ecancer.2015.522. eCollection 2015.
High-resolution melt analysis (HRMA) is a cheap and reliable post-polymerase chain reaction (PCR) cancer mutation screening technique, which is fast gaining clinical relevance. The HRMA capabilities of the LightScanner (Idaho Technology) have been severally studied. However, the ABI 7500 HRM has not been tested against the purpose-built HRM instrument such as the LightScanner. DNA from formalin-fixed, paraffin-embedded gastric cancer, colorectal cancer, and normal tissue as well as from colorectal cancer cell lines were amplified at exons 2, 3, and 4 of KRAS, and at exons 11 and 15 of BRAF in the ABI 7500 fast real-time PCR machine and subjected to melting both on the ABI and on the LightScanner. HRMA data were analysed with the ABI HRM software v2.0.1 and the LightScanner Call-IT 2.5. We tested the ABI 7500 HRM for internal precision, accuracy, sensitivity, and specificity at mutation screening relative to the LightScanner, using crude percentage concordance, kappa statistics, and the area under the receiver operator characteristics (AUROC) curve on SPSS version 19. The results show that the ABI 7500 HRMA has a high internal precision, and excellent concordance, sensitivity, and specificity at mutation screening compared with the LightScanner. However, in contrast to the LightScanner HRM software analysis, the ABI HRM software v.2.0.1, cannot distinguish real from certain pseudovariations in PCR amplicons that are sometimes brought about by the artefacts of the melting process. In conclusion, the ABI HRM has a comparable performance level with the LightScanner, although in certain respects mentioned previously, the LightScanner has an edge over the ABI.
高分辨率熔解分析(HRMA)是一种经济且可靠的聚合酶链反应(PCR)后癌症突变筛查技术,其在临床上的相关性正迅速提升。人们已对LightScanner(爱达荷技术公司)的HRMA性能进行了多项研究。然而,ABI 7500 HRM尚未与诸如LightScanner这类专门设计的HRM仪器进行对比测试。在ABI 7500快速实时PCR仪中,对来自福尔马林固定、石蜡包埋的胃癌、结直肠癌及正常组织以及结直肠癌细胞系的DNA进行KRAS基因第2、3和4外显子以及BRAF基因第11和15外显子的扩增,并在ABI仪器和LightScanner上进行熔解分析。使用ABI HRM软件v2.0.1和LightScanner Call-IT 2.5对HRMA数据进行分析。我们在SPSS 19版本上,通过粗略百分比一致性、kappa统计以及受试者操作特征曲线下面积(AUROC)曲线,测试了ABI 7500 HRM在突变筛查方面相对于LightScanner的内部精密度、准确性、敏感性和特异性。结果表明,与LightScanner相比,ABI 7500 HRMA具有较高内部精密度,在突变筛查方面具有出色的一致性、敏感性和特异性。然而,与LightScanner HRM软件分析不同,ABI HRM软件v.2.0.1无法区分PCR扩增子中有时由熔解过程假象导致的真实变异与某些假变异。总之,ABI HRM与LightScanner具有相当的性能水平,尽管在前面提到的某些方面,LightScanner比ABI更具优势。